Campus Lighting


AR07
- Power: 100W–500W
- Lumens: Up to 75,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Distribution: Type II / Type III / Type IV / Type V
- Mount: Slip Fitter / Trunnion / Arm
- Dimming: 0–10V

AR11
- Power: Multiple Wattages Available
- Lumens: Up to 150 lm/W
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Tunable)
- Distribution: Type II / III / IV / V
- IP Rating: IP65
- Dimming: Motion Sensor / Dimmable

PT-LD03
- Power: 30W–120W
- Lumens: Up to 18,600 lm
- Voltage: 100–277V AC
- CCT: 3000K–5000K
- Distribution: Type II (T2)
- Mount: Pole Mount / Arm Mount
- IP Rating: IP67

WK04
- Power: 40W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K / 5700K
- Beam Distribution: 80° × 110°
- Mount: Wall Mount
- Dimming: 0–10V

WK05
- Power: 30W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Distribution: 60° × 120°
- Mount: Wall Mount
- Dimming: 0–10V

WK06
- Power: 20W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Distribution: 65° × 95°
- Mount: Wall Mount
- Dimming: 0–10V

WK07
- Power: 20W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Distribution: Type III
- Mount: Wall Mount
- Dimming: 0–10V

WK08
- Power: 30W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Distribution: 80° × 100°
- Mount: Wall Mount
- Dimming: 0–10V

BD Series
- Power: 14W–24W (Selectable)
- Lumens: Up to 3,600 lm
- Voltage: 120–277V / 120–347V
- CCT: 3000K / 4000K / 5000K
- Beam Angle: 120°
- Mount: Bollard Base Mount
- IP Rating: IP65
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Campus lighting must support pedestrian movement, vehicle circulation, wayfinding, nighttime visibility, and outdoor operations across roads, parking lots, pathways, entrances, courtyards, landscaped areas, and residence zones.
These areas should not use one fixture type or universal light level. Effective campus lighting matches illuminance, uniformity, optical distribution, mounting height, CCT, controls, and glare protection to each zone.
STARLAKE supports outdoor campus projects with multiple LED fixture families, photometric distributions, mounting configurations, voltage options, and control-ready solutions.
One Campus Requires Multiple Lighting Strategies
Campus lighting should be divided into functional zones before fixtures are selected.
Pedestrian routes require consistent illumination and useful vertical visibility. Roads and parking lots need controlled pole-mounted distributions, while entrances and building perimeters require sufficient recognition and circulation lighting without excessive spill into windows or adjacent properties.
| Campus Area | Primary Objective | Key Design Considerations |
|---|---|---|
| Walkways and pathways | Pedestrian visibility and wayfinding | Uniformity, vertical visibility, glare, CCT |
| Campus roads | Driver and pedestrian visibility | Distribution, pole spacing, cutoff |
| Parking lots | Consistent area coverage | Pole layout, distribution, controls |
| Building entrances | Recognition and transition | Vertical illuminance, glare, facial visibility |
| Building perimeters | Security and circulation | Wall distribution, cutoff, light trespass |
| Courtyards and common areas | Comfort and orientation | Lower light levels, CCT, visual hierarchy |
| Landscaped areas | Guidance with limited spill | Shielding, targeted illumination, warm CCT |
The objective is not equal brightness across the campus, but appropriate light for each visual task while controlling glare, spill, and unnecessary energy use.
Match the Fixture Type to the Campus Zone
Fixture selection should follow site geometry, mounting conditions, and visual tasks rather than wattage alone.
Roads and Parking Areas
Pole-mounted LED area lights can serve campus roads, vehicle entrances, intersections, and parking areas. Their optical distribution determines how effectively light reaches the required surface from a given pole position.
| Distribution | Typical Campus Application |
|---|---|
| Type II | Narrow roads and linear routes |
| Type III | Roadways and parking-lot edges |
| Type IV | Perimeter and edge conditions |
| Type V | Open parking areas and common spaces |
STARLAKE area-light configurations support Type II, Type III, Type IV, and Type V distributions, allowing the light pattern to be matched to pole position, road width, parking geometry, and target coverage.
Walkways and Landscaped Routes
LED bollard lights can provide pedestrian-scale illumination along pathways, courtyards, landscaped routes, and building approaches.
Because pedestrians view these fixtures at close range, source brightness and glare require careful control. Spacing should also avoid alternating bright pools and dark gaps along the route.
Entrances and Building Perimeters
Wall-mounted luminaires can illuminate entrances, service areas, circulation routes, and building perimeters without requiring additional poles near the structure.
Traditional, slim, adjustable, and full-cutoff configurations provide different coverage and optical control. Full-cutoff designs are particularly relevant where uplight, forward glare, or spill toward residence halls and neighboring properties must be restricted.
Design for Illuminance, Uniformity, and Visibility
Lumens measure luminaire output, not the illuminance that reaches a campus surface. Mounting height, spacing, optics, site geometry, landscaping, surface reflectance, and surrounding structures determine the actual lighting result.
Uniformity Matters Along Pedestrian Routes
For walkways and roads, large differences between bright and dark areas increase visual adaptation demands and can leave sections of a route poorly defined. Fixture spacing and optical distribution therefore need to be evaluated together with average illuminance.
The campus design references supplied for this page include average maintained values around 1.0–2.5 fc for pedestrian walkways, 1.0–3.0 fc for campus roads, and 1.5–2.0 fc for some parking applications. Institutional references may use different targets and uniformity ratios.
These figures are design references, not universal requirements. Final criteria should follow applicable campus standards, local requirements, site conditions, and project-specific lighting design.
Vertical Light Supports Recognition
Horizontal illuminance supports visibility of pavement, curbs, steps, and obstacles, while vertical illuminance contributes to recognition of signs, entrances, objects, and pedestrians.
A route can therefore meet a horizontal illuminance target while still providing weak recognition if most of the light is concentrated on the ground. This distinction is particularly relevant at pathways, intersections, and building entrances.
Verify the Layout With Photometric Analysis
Fixture wattage and lumen output cannot determine pole spacing or campus coverage by themselves. Two luminaires with similar output can produce substantially different results because their optical distributions differ.
Fixture-specific IES data should be evaluated against actual site geometry to assess:
Average and minimum illuminance
Uniformity
Coverage between poles
Potential dark areas
Optical distribution
Spill beyond the intended area
Interaction between adjacent luminaires
This becomes especially important where buildings, trees, roads, parking areas, pathways, and property boundaries affect the same lighting environment.
Final layouts should be checked against project requirements and, where appropriate, verified through field measurements after installation.
Control Glare, Uplight, and Light Trespass
Increasing output can reduce visibility if it introduces glare, excessive contrast, or spill. Campus luminaires should direct useful light toward intended roads, parking surfaces, pathways, and entrances.
Full-cutoff or well-shielded luminaires can be particularly useful around:
Residence halls
Campus boundaries
Natural areas
Pedestrian routes
Courtyards
Neighboring residential communities
Where the BUG system is used, Backlight, Uplight, and Glare ratings should be evaluated against installation requirements. Some campus standards in the supplied references specify U0 where uplight is not permitted.
Light trespass is also affected by mounting height, fixture tilt, orientation, distribution, output, and distance from the property boundary. A suitable luminaire can still produce unwanted spill if installed or aimed incorrectly.
Select CCT for the Campus Environment
CCT can vary by campus zone rather than being standardized across the entire property.
2700K to 3000K can suit pathways, courtyards, landscaped areas, and spaces where a warmer nighttime appearance or reduced short-wavelength output is preferred. 4000K may be specified for roads, parking areas, and entrances where a more neutral appearance is desired.
STARLAKE configurations supplied for this application include selectable 3000K, 4000K, and 5000K options, depending on the luminaire.
Higher CCT does not automatically provide better visibility. CCT should be evaluated together with illuminance, uniformity, CRI, glare, optical distribution, and the surrounding nighttime environment.
Adapt Lighting Output to Campus Activity
Campus traffic often declines substantially after peak evening periods. Roads, parking areas, and pedestrian routes therefore do not necessarily require full output throughout the night.
Depending on project requirements, controls can include:
Photocells
Time schedules
0–10V dimming
Motion or occupancy sensing
Bi-level operation
Zoned control
Central lighting management
For example, a parking area can operate at its designed level during active periods and reduce output later at night, with sensor-based response where appropriate.
Several STARLAKE outdoor configurations support 0–10V dimming, while selected solutions can incorporate sensing and other control options. Luminaire, driver, sensor, and control-system compatibility should be confirmed before specification.
Specify Campus Lighting for Outdoor Conditions
Outdoor campus luminaires face repeated exposure to rain, humidity, dust, temperature changes, and seasonal weather. Environmental protection, electrical configuration, mounting hardware, and maintenance access should therefore be considered during specification.
STARLAKE configurations supplied for this application include outdoor options rated IP65 and IP67, depending on the product.
Available electrical configurations across relevant fixture families include 120–277V, 120–347V, and selected 277–480V options. Depending on the fixture family, mounting options include slip fitter, trunnion, arm, pole, bollard, and wall mounting.
For large campuses, standardizing adaptable fixture families across multiple zones can also reduce replacement complexity and the number of spare configurations that maintenance teams need to manage.
Retrofit Existing Campus Lighting Based on Site Performance
Older campuses may still use metal-halide, high-pressure sodium, or other legacy outdoor fixtures. LED replacement should not be based on wattage equivalence alone.
Retrofit evaluation should account for existing pole height and spacing, maintained output, optical distribution, dark or overlit areas, voltage, controls, and required lighting criteria.
A lower-wattage LED luminaire with better optical control can place more useful light on the intended surface than a higher-wattage legacy fixture. Retrofit selection should therefore be based on photometric performance at the site rather than nominal wattage.
What Information Is Needed for a Campus Lighting Project?
Accurate site information allows fixture type, output, optics, mounting, controls, and electrical configuration to be evaluated together before specification or quotation.
Useful inputs include:
Site plan and dimensions
Roads, pathways, parking areas, and building locations
Existing or proposed pole positions
Pole and wall mounting heights
Target illuminance and uniformity
Existing fixture information for retrofit projects
Voltage
Preferred CCT and CRI
Control requirements
Environmental conditions
Mounting requirements
Certification requirements
Project quantity and schedule
Wattage should be an output of the selection process rather than its starting point.
Campus Lighting Manufacturing and Project Support
Campus projects can involve multiple fixture families, optical distributions, mounting configurations, controls, and delivery phases, making product consistency and supply continuity relevant alongside photometric performance.
STARLAKE has manufactured LED lighting products since 2010, with manufacturing operations in Shenzhen and Cambodia. Its engineering resources cover optics, driver and power-supply development, thermal management, mechanical engineering, digital controls, and new product development.
For project, distributor, and OEM/ODM requirements, STARLAKE supports optical and electrical configurations, mounting options, sensor and control integration, structural customization, private labeling, packaging, certification coordination, and production engineering.
Bulk production orders undergo an 8-hour aging test, while new products undergo 30-day continuous 24/7 high-temperature testing as part of product validation. STARLAKE also operates warehouses in Ohio and California for local fulfillment of selected stocked products in the U.S. market.
Certification and inventory availability should be confirmed for the specific model and project.
Plan Your Campus Lighting Project With STARLAKE
Effective campus lighting starts with site zoning, followed by selection of the appropriate fixture type, optical distribution, mounting condition, illuminance criteria, CCT, and control strategy for each area.
For university, college, school, institutional, or campus LED retrofit projects, provide STARLAKE with your site plan, pole locations and heights, target lighting criteria, voltage, control requirements, and existing fixture schedule where applicable. These inputs can be used to evaluate suitable fixture configurations and prepare a project quotation.