Commercial Building Lighting Solutions


AR07
- Power: 100W–500W
- Lumens: Up to 75,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Distribution: Type II / Type III / Type IV / Type V
- Mount: Slip Fitter / Trunnion / Arm
- Dimming: 0–10V

AR11
- Power: Multiple Wattages Available
- Lumens: Up to 150 lm/W
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Tunable)
- Distribution: Type II / III / IV / V
- IP Rating: IP65
- Dimming: Motion Sensor / Dimmable

PT-LD03
- Power: 30W–120W
- Lumens: Up to 18,600 lm
- Voltage: 100–277V AC
- CCT: 3000K–5000K
- Distribution: Type II (T2)
- Mount: Pole Mount / Arm Mount
- IP Rating: IP67

WK04
- Power: 40W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K / 5700K
- Beam Distribution: 80° × 110°
- Mount: Wall Mount
- Dimming: 0–10V

WK05
- Power: 30W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Distribution: 60° × 120°
- Mount: Wall Mount
- Dimming: 0–10V

WK06
- Power: 20W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Distribution: 65° × 95°
- Mount: Wall Mount
- Dimming: 0–10V

WK07
- Power: 20W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Distribution: Type III
- Mount: Wall Mount
- Dimming: 0–10V

WK08
- Power: 30W–120W (Selectable)
- Lumens: Up to 16,800 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Distribution: 80° × 100°
- Mount: Wall Mount
- Dimming: 0–10V

BPL Series
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: DLC 6.0 Premium/ETL.
- Recommended Use: New construction or remodel, Office, Schools, Healthcare facilities, Institutions and commercial applications.
- Distribution: 120°.

TRF14
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: ETL/DLC 6.0 Premium.
- Recommended Use: School, office, hospitality, education, bank, healthcare and more.
- Distribution: 120°.

SP05
- Housing: Stamping process heat sink to improve production efficiency.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling installation, Suspension rod.
- Certification list: UL/DLC 6.0 Premium.
- Recommended Use: Schools, hospitals, supermarkets, offices, warehouses.
- Distribution: 120°.
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Commercial building lighting must support different visual tasks within the same property. Offices require uniform task illumination and glare control, customer-facing areas place greater emphasis on color quality and presentation, while entrances, perimeters, and parking areas require controlled exterior distribution.
Lighting design should therefore begin with how each space is used, rather than fixture wattage or total lumens.
STARLAKE provides commercial LED lighting solutions for interior and exterior applications, supported by lighting engineering, manufacturing, OEM and ODM development, quality control, and U.S.-based inventory for selected products.
Commercial Building Lighting at a Glance
A commercial building should be planned as a lighting system rather than as a collection of independently selected fixtures.
Interior workspaces prioritize illuminance, uniformity, glare, color quality, and controls. Public-facing spaces add architectural presentation and visual hierarchy, while exterior zones require greater attention to photometric distribution, mounting geometry, environmental protection, and nighttime visibility.
A practical design sequence is:
Space and visual task → target illuminance → mounting conditions → light distribution → fixture output and spacing → color quality → controls → verification
This sequence reduces the risk of selecting excessive output to compensate for poor distribution or inappropriate fixture placement.
How to Plan Commercial Building Lighting by Zone
Light level, CCT, fixture type, distribution, and controls should follow the function of each building zone.
| Building Zone | Primary Lighting Goal | Key Design Priorities |
|---|---|---|
| Offices and workspaces | Comfortable task visibility | Illuminance, glare, uniformity, CCT, controls |
| Lobbies and reception | Navigation and visual presentation | CRI, CCT, contrast, architectural integration |
| Corridors and common areas | Safe circulation | Uniformity, appropriate light level, occupancy controls |
| Retail and customer areas | Merchandise and visual focus | Color rendering, accent distribution, contrast |
| Entrances and exterior walls | Visibility and transition | Mounting height, cutoff, wall and ground distribution |
| Parking and site areas | Broad nighttime coverage | Pole height, spacing, optical distribution, uniformity |
Offices and Workspaces
Offices typically require broad, consistent illumination across desks and work surfaces while limiting excessive source brightness within normal viewing angles.
Panel, troffer, and linear fixtures can provide general illumination, but the final configuration should account for ceiling height, workstation layout, computer use, daylight contribution, required illuminance, and controls.
CCT should match the visual task and interior environment rather than being treated as a fixed office specification.
Lobbies, Corridors, and Common Areas
Lobbies often combine ambient illumination with focused light on reception desks, walls, signage, artwork, or architectural elements. This creates visual hierarchy without requiring uniformly high illumination throughout the space.
Corridors and elevator approaches generally require less task illumination than offices but still need sufficient uniformity for circulation. Occupancy controls can reduce operating hours in intermittently used areas.
Retail and Customer-Facing Areas
Retail lighting must support circulation while directing visual attention toward merchandise and selected surfaces.
Color rendering becomes particularly important for clothing, finishes, food, cosmetics, and other color-sensitive products. Ambient and accent lighting can provide contrast and hierarchy without increasing the general illumination level across the entire retail area.
Exterior Walls, Entrances, and Parking Areas
Exterior commercial lighting depends heavily on building and site geometry.
Wall-mounted luminaires can serve entrances, pedestrian circulation, and building perimeters, while pole-mounted area lights provide broader parking and site coverage.
Type II, III, IV, and V distributions suit different pole positions and site geometries. Pole height, spacing, mounting orientation, property boundaries, and adjacent areas should therefore be evaluated together rather than selecting fixtures from wattage alone.
Design for Illuminance, Distribution, and Uniformity
Total lumen output does not indicate how much useful light reaches a work surface, corridor, reception counter, walkway, or parking area. Illuminance measures the light reaching a surface, usually in lux or foot-candles.
The resulting illuminance depends on fixture output, optical distribution, mounting geometry, spacing, room dimensions, surface reflectance, obstructions, and site conditions.
Two fixtures with similar lumen output can therefore produce different average illuminance, minimum illuminance, and uniformity.
Compact or directional LED sources also require appropriate optics, diffusion, or spacing to prevent concentrated bright zones, dark areas, or visible individual emitters.
Where layout performance is critical, fixture-specific IES data should be used to verify illuminance, distribution, and uniformity before installation.
Control Glare Without Losing Useful Light
Excessive source brightness or strong contrast within the normal field of view can create visual discomfort even when measured illuminance is adequate.
This is particularly relevant in offices, meeting rooms, reception areas, and other spaces with prolonged occupancy.
Diffusers, lenses, shielding, cutoff, mounting position, and fixture spacing can reduce direct brightness while maintaining useful illuminance on the intended surfaces.
Glare control should therefore be evaluated together with required illuminance rather than addressed by simply reducing or increasing fixture output.
Match CCT and Color Quality to the Space
CCT should reflect the function and visual character of each commercial zone rather than being standardized across the entire building.
Warmer light can complement hospitality-oriented and relaxed spaces, while neutral white is commonly used in offices and contemporary commercial interiors. Other applications may specify cooler light where appropriate to the visual environment.
CRI becomes more relevant where occupants evaluate merchandise, food, finishes, artwork, materials, or skin tones.
Color consistency between neighboring luminaires also matters in large installations because visible differences in CCT or color appearance can become noticeable across continuous ceilings and repeated fixture layouts.
CCT and color-rendering requirements should therefore be specified by zone and application rather than selected as isolated catalog values.
Use Lighting Controls Where They Create Value
Occupancy and daylight conditions vary throughout a commercial building, allowing lighting output and operating time to be adjusted to actual demand.
Common strategies include:
0–10V dimming for adjustable output
Occupancy sensing for intermittently occupied areas
Daylight harvesting where natural light contributes to required illuminance
Scheduled control based on operating hours
Addressable control systems for fixture- or zone-level management
DALI can provide digital addressing and grouped control where the selected luminaires and control architecture support it.
Control requirements should be established before fixture selection because driver compatibility, wiring, sensors, commissioning, and control architecture affect the complete specification.
Energy codes such as IECC and ASHRAE 90.1 may also require controls in nonresidential buildings. Applicable provisions should be confirmed for the project type and jurisdiction.
Coordinate Interior and Exterior Lighting
Commercial occupants often move from parking areas through entrances and lobbies into corridors, elevators, and workspaces. Lighting these areas independently can create abrupt brightness transitions or gaps in nighttime visibility.
Area lighting can provide site-level illumination, wall-mounted fixtures can cover entrances and perimeter circulation, and interior luminaires can transition toward the light levels required for indoor tasks.
Coordinating interior and exterior systems can also simplify fixture schedules, control zoning, replacement planning, and future sourcing.
Retrofit Commercial Buildings by Performance, Not Wattage
Existing commercial properties may use fluorescent troffers, fluorescent tubes, older wall packs, or HID exterior fixtures. LED replacements should not be selected by wattage equivalence alone.
A better retrofit decision chain is:
Existing fixture → maintained light level → mounting and spacing → required illumination → LED distribution and output → controls → installation → total installed cost
Existing systems may have lost output through lamp aging, dirty optics, ballast condition, or other degradation. Matching original wattage or nominal lumen ratings can therefore produce excessive illumination, insufficient illumination, or unsuitable distribution.
Before selecting replacements, evaluate the existing fixture type, system wattage, mounting configuration, spacing, voltage, controls, operating hours, and required light level.
Where layout performance matters, verify the replacement using fixture-specific photometric data.
Evaluate Lifecycle Cost, Not Fixture Price Alone
At building scale, energy, installation, controls, maintenance access, and replacement frequency can have greater financial impact than differences in fixture purchase price.
A lifecycle comparison can include:
Fixture cost + installation + controls + access equipment + energy + expected maintenance − applicable incentives
Maintenance costs may include labor, lifts, ceiling access, after-hours work, replacement inventory, and disruption to building operations.
Thermal management also affects long-term LED performance. Heat must transfer from the LED junction through the board and luminaire structure into the surrounding environment, so fixture thermal design should be considered alongside rated life and maintenance expectations.
What We Need for a Commercial Lighting Quote
Project information should be evaluated before an individual fixture configuration is selected.
For interior projects, useful inputs include:
Building type and application
Floor plans or room dimensions
Ceiling and mounting heights
Target illuminance where specified
Existing fixtures for retrofit projects
Operating voltage
Preferred CCT and color-quality requirements
Dimming and control requirements
Installation conditions
Certification requirements
Project quantity and schedule
For exterior areas, also provide pole locations and heights, wall mounting positions, parking geometry, property boundaries, roadways, and other site constraints.
STARLAKE can use these inputs to narrow fixture configurations and identify areas requiring IES-based photometric verification.
Why STARLAKE for Commercial Building Lighting
Commercial projects can involve multiple fixture categories, electrical configurations, controls, certifications, packaging requirements, inventory planning, and replenishment schedules.
STARLAKE has manufactured LED lighting products since 2010, with approximately 280,000 sq.ft of production space and manufacturing operations in Shenzhen and Cambodia. More than 50 engineering professionals support LED integration, power supplies, optics, thermal management, controls, and mechanical design.
For OEM and ODM programs, STARLAKE supports specification adjustment, optical and electrical configuration, structural customization, private labeling, packaging, certification coordination, validation, and production implementation.
Bulk production orders undergo an 8-hour aging test before shipment, while new products undergo 30-day continuous high-temperature testing as part of product validation.
Warehouses in Ohio and California provide U.S.-based inventory and fulfillment support for selected products alongside factory-direct manufacturing.
This structure allows commercial buyers to coordinate engineering customization, manufacturing, validation, and selected local inventory within the same sourcing program.
Plan Your Commercial Building Lighting Project
Commercial building lighting should match visual tasks, illuminance, distribution, glare control, color quality, controls, installation conditions, and lifecycle requirements to each part of the property.
STARLAKE supports commercial lighting brands, distributors, contractors, and project buyers with interior and exterior LED lighting, engineering coordination, OEM and ODM manufacturing, quality control, and U.S.-based supply support.
Send us your floor plans or site drawings, mounting heights, target light levels, voltage, control requirements, quantities, and project schedule. STARLAKE can use these inputs to evaluate suitable lighting configurations and prepare a quotation.