LED Gym Lighting for Commercial Fitness Centers


UFO11
- Power: 100W–240W
- Lumens: Up to 36,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K / 5700K
- Beam: 90° / 110°
- Mount: Hook / Loop / Yoke
- Dimming: 0–10V

UFO12
- Power: 100W–240W
- Lumens: Up to 36,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K / 5700K
- Beam Angle: 90° / 110°
- Mount: Loop / Hook / Yoke
- Dimming: 0–10V

LHB06
- Power: 80W–400W
- Lumens: Up to 60,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3500K / 4000K / 5000K / 5700K
- Beam Angle: 90°
- Mount: Suspension / Chain / Ceiling
- Dimming: 0–10V

LHB07
- Power: 80W–300W
- Lumens: Up to 45,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3500K / 4000K / 5000K
- Beam Angle: 90°
- Mount: Suspension / Chain / Ceiling
- Dimming: 0–10V

LHB08 Linear LED High Bay Light
- Power: 80W–300W
- Efficacy: Up to 140 lm/W
- Voltage: AC120–277V / AC120–347V / AC277–480V
- CCT: 3000K / 3500K / 4000K / 4500K / 5000K / 5700K
- Beam Angle: 90°
- Dimming: 0–10V
- IP Rating: IP44 / Damp Location
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Good gym lighting must balance task illuminance, uniformity, glare, and energy use across spaces where members train in different positions and frequently look toward overhead luminaires.
STARLAKE provides LED gym lighting for commercial fitness centers, indoor training facilities, and recreational gymnasiums. UFO and linear LED high bays cover 80W to 400W, with selected models delivering up to 60,000 lumens, multiple voltage configurations, and 0–10V dimming.
Mounting height, activity zones, fixture spacing, and optical distribution should determine the lighting system rather than wattage alone.
What Makes Gym Lighting Different
High-ceiling gyms require light to reach training surfaces from elevated mounting positions while maintaining uniformity and visual comfort.
Unlike many industrial environments, gym activities such as bench presses, pull-ups, overhead exercises, and floor training regularly place ceiling luminaires within the user’s field of view.
Three factors therefore deserve particular attention:
Uniformity – Reduce excessive differences between bright and dark areas.
Glare control – Limit uncomfortable source brightness when users look upward.
Light distribution – Spread useful illumination across training areas rather than concentrating it directly beneath fixtures.
These factors make photometric distribution as important as total lumen output.
Design for Uniformity, Not Just Lumens
Compact, directional LED sources can create strong center intensity and rapid falloff without suitable secondary optics and spacing.
Wider distributions increase lateral coverage and overlap, while tighter distributions can maintain stronger intensity from higher mounting positions. The appropriate option depends on the room geometry and mounting height.
STARLAKE UFO high bays are available with 90° and 110° beam options, while the current linear high bay range includes 90° configurations.
A practical selection sequence is:
Mounting height → target illuminance → distribution → lumen output → fixture spacing → photometric verification
Fixture-specific IES files should verify final illuminance and uniformity rather than relying on fixed wattage or lumen rules.
Match the Lighting to Each Gym Zone
Different activity zones create different visual and operational requirements.
Strength and Free-Weight Areas
Strength areas require particular attention to overhead glare because members frequently look upward during bench presses, shoulder exercises, and pull-ups.
Racks, machines, and people also create shadows around equipment. Fixture placement and overlapping distributions should maintain visibility without severe bright-to-dark transitions.
Cardio Areas
Rows of treadmills, bikes, and other cardio equipment benefit from consistent illumination across long training zones.
Linear high bays can suit rectangular or row-based equipment layouts, while UFO high bays can provide repeated coverage across more open cardio areas.
Functional and Open Training Areas
Functional training can involve kettlebells, sleds, ropes, and body-weight exercises, with users moving in multiple directions.
Uniform horizontal illumination helps users identify equipment, floor boundaries, and nearby people. Separate control zones can also reduce output when these areas are unoccupied.
Studios and Lower-Ceiling Spaces
Yoga, stretching, and similar lower-ceiling studios may not require high-bay fixtures.
Panel, troffer, or other low-profile commercial luminaires may better match their ceiling height and visual requirements. Fixture selection should therefore follow each zone rather than applying one luminaire type throughout the facility.
UFO vs. Linear High Bay for Gym Lighting
UFO and linear LED high bays can both serve commercial gyms, but their geometry suits different layouts.
| Design Factor | UFO High Bay | Linear High Bay |
|---|---|---|
| Best-fit layout | Open training areas | Rectangular and row-based areas |
| Fixture geometry | Compact circular | Elongated rectangular |
| STARLAKE power range | 100W–240W | 80W–400W |
| Maximum output | Up to 36,000 lm | Up to 60,000 lm on selected models |
| Current beam options | 90° / 110° | 90° |
| Dimming | 0–10V | 0–10V |
| Typical selection reason | Flexible repeated coverage | Matches linear space geometry |
UFO fixtures can provide a straightforward repeated layout across open free-weight or functional training floors. Linear high bays can align more naturally with long cardio zones and rectangular equipment arrangements.
Fixture shape alone does not determine coverage. Where either format could work, compare fixture-specific IES data against the actual floor plan.
Select Output, CCT and Controls Around the Facility
STARLAKE’s current gym-compatible high bay range covers approximately 80W to 400W. Selected linear models reach 60,000 lumens, while current UFO models reach up to 36,000 lumens.
As mounting height increases, maintaining target illuminance may require higher output, different optics, revised spacing, or a combination of these changes. A fixed ceiling-height-to-wattage rule cannot account for these variables.
Available high-bay CCT configurations range from 3000K to 5700K depending on the model. Neutral and cooler CCTs are commonly considered for active training areas, while warmer settings may suit lower-intensity spaces.
Current UFO and linear high bays support 0–10V dimming. Where compatible controls are used, cardio, strength, functional training, and circulation zones can operate independently rather than keeping the entire facility at full output.
Electrical configurations include 120–277V, 120–347V, and, on selected linear models, 277–480V. Available voltage should be confirmed for the selected model.
Gym Lighting Range at a Glance
80W–400W
High Bay Power Range
Up to 60,000 lm
Selected Linear High Bays
0–10V
Dimming
Up to 480V
Selected Configurations
Retrofit Gym Lighting by Performance, Not Wattage
Older fitness centers and gymnasiums may still use metal-halide, HID, or fluorescent systems.
LED conversion can reduce connected load while adding instant-on operation and dimming, but the replacement should be based on required lighting performance rather than a fixed wattage equivalence.
Before selecting a replacement, document:
Existing fixture type and system wattage
Fixture quantity and spacing
Mounting height
Existing light levels
Available voltage
Current controls
Areas with glare or poor uniformity
Required light levels after retrofit
Maintained output of the existing system, mounting geometry, spacing, and LED optical distribution all affect the required replacement configuration.
The proposed layout should then be verified with actual photometric data.
Replace the required lighting performance, not simply the existing wattage.
Design for Long Operating Hours and Lower Maintenance
Commercial gyms can operate from early morning until late at night, while high-mounted fixtures may require lifts, temporary closures, or after-hours access when service is needed.
Thermal design therefore affects maintenance as well as luminaire performance. Heat generated at the LED junction must transfer through the board, thermal interfaces, and housing before dissipating into the surrounding environment.
For commercial projects, lifecycle evaluation should consider fixture construction, driver configuration, thermal management, mounting hardware, operating hours, service access, warranty support, and future replacement availability.
For fitness chains and other multi-location operators, product continuity also matters when later replacement fixtures need to remain compatible with earlier installations.
What We Need for a Gym Lighting Layout
Fixture selection should begin with the facility geometry and operating requirements.
For a new gym or retrofit project, provide:
Floor plan and room dimensions
Ceiling and fixture mounting height
Main activity zones
Existing fixture locations for retrofit projects
Target illuminance if specified
Available electrical voltage
Preferred CCT
Dimming or control requirements
Existing fixture type and wattage for retrofits
Required product certifications
Fixture-specific IES data can then be used for final photometric verification because room geometry, surface reflectance, equipment, and optical distribution affect the installed result.
Commercial Gym Lighting Manufacturing and Project Support
For distributors, lighting brands, contractors, and multi-location fitness operators, sourcing requirements can extend beyond photometric performance to customization, manufacturing consistency, quality control, and long-term supply.
Founded in 2010, STARLAKE combines manufacturing operations in Shenzhen and Cambodia with engineering capabilities covering optics, drivers, thermal management, mechanical design, and lighting controls.
More than 50 engineers and 30+ quality-control professionals support product development and manufacturing. OEM and ODM services can include optical and electrical configuration, structural customization, private labeling, packaging, and certification coordination.
Bulk production orders undergo an 8-hour aging test before shipment, while new products undergo extended high-temperature validation during product development.
For North American customers, warehouses in Ohio and California provide local inventory and fulfillment support for selected products.
This structure supports individual commercial gym projects as well as repeat purchasing, customized programs, and multi-location rollouts.
Build Your Gym Lighting Around the Space
Effective LED gym lighting depends on matching output, optical distribution, mounting height, spacing, glare control, and controls to the facility and its activity zones.
STARLAKE offers UFO and linear high bay configurations from 80W to 400W, with selected models delivering up to 60,000 lumens, multiple voltage options, and 0–10V dimming.
For individual facilities, multi-location projects, or OEM and ODM programs, provide your floor plan, mounting height, voltage, activity zones, and project requirements. STARLAKE can evaluate suitable fixture configurations and support photometric planning.





