For pedestrian-scale commercial walkways, shielded LED bollard lights are often a strong starting choice when their optics provide sufficient coverage without excessive glare. Low-profile path lights suit narrow garden paths and landscaped courtyards, while recessed step lights illuminate stairs and changes in elevation. Adjustable spotlights are better suited to trees and architectural features than general walkway lighting.
Solar pathway lights may suit remote or supplementary locations where electrical wiring is difficult, but their operating hours must be verified against seasonal solar conditions and usable battery capacity.
For wide routes, security-sensitive areas, or locations where people and signs must be clearly visible, bollards alone may be insufficient. The final design should be checked against project-specific lighting requirements rather than fixture type or lumen output alone.
Which Landscape and Pathway Lights Are Best?
The most suitable fixture depends on the area being illuminated, required coverage, installation conditions, and maintenance access.
| Lighting Type | Best Application | Main Advantage | Main Limitation |
|---|---|---|---|
| Shielded LED bollard lights | Office parks, campuses, pedestrian-scale walkways | Controlled light distribution near pedestrian level | May require supplementary lighting for demanding visibility tasks |
| Low-profile path lights | Garden paths, landscaped courtyards | Localized illumination with limited visual intrusion | Coverage may be insufficient on wider paths |
| Recessed step and wall lights | Stairs, retaining walls, building approaches | Illuminates changes in elevation without freestanding posts | Requires suitable construction and mounting details |
| In-ground lights | Architectural accents, trees, pathway boundaries | Minimal above-ground obstruction | Drainage, surface loading, and service access |
| Landscape spotlights | Trees, sculptures, façades, monuments | Adjustable directional illumination | Does not necessarily illuminate adjacent walking surfaces |
| Solar pathway lights | Remote or supplementary paths | Avoids extensive electrical trenching | Output and runtime depend on energy collection and storage |
Key Selection Criteria
Before choosing a fixture, establish the following conditions.
- Visual task: Is the objective to illuminate a walking surface, identify pedestrians, mark a change in elevation, or highlight a landscape feature?
- Optical performance: Does the distribution provide adequate minimum illuminance and acceptable uniformity without excessive glare?
- Mounting conditions: Are the required foundation, wall, ground, or recessed mounting details available?
- Environmental exposure: Will the fixture encounter irrigation, standing water, coastal corrosion, surface loading, or mechanical impacts?
- Maintenance: Can drivers, electrical connections, and replacement components be accessed without extensive demolition or landscape disturbance?
- Site appearance: Can the luminaire meet its functional requirements without obstructing circulation or conflicting with the landscape design?
These conditions determine which fixture categories should proceed to photometric and technical evaluation.
Comparing the Main Types of Landscape and Pathway Lighting

LED Bollard Lights for Commercial Walkways
LED bollards illuminate pedestrian routes from a relatively low mounting position, avoiding the need for taller poles in suitable locations.
Their performance depends on the relationship between mounting height, optical distribution, and walkway width.
A shielded bollard directs light toward the intended walking surface while limiting direct visibility of the light source. Designs with exposed, highly luminous diffusers may produce uncomfortable glare when viewed at pedestrian eye level.
For a narrow walkway, a suitable distribution may provide continuous illumination from fixtures installed along one side. Wider routes may require different optics, additional fixtures, or another lighting layer.
Bollards should not automatically serve as the only luminaires in areas with demanding security, pedestrian identification, or traffic-related visibility requirements. Additional lighting at a different mounting height, such as appropriately designed LED area lighting, may be needed to illuminate people, signs, intersections, and surrounding areas.
Mechanical exposure also matters. Foundations, anchoring, housing construction, and placement should account for landscaping equipment, irrigation, and possible impacts.
Bollards are also part of the broader range of LED garden and lawn lighting used to coordinate pedestrian routes with surrounding landscaped areas.
Best suited to: Primary pedestrian-scale routes where optical calculations confirm suitable coverage and glare control.
Less suitable for: Locations where freestanding posts obstruct movement or where the required visibility cannot be achieved through bollard lighting alone.
Low-Profile Path Lights for Gardens and Courtyards
Low-profile path lights illuminate walking surfaces from positions close to the ground.
They are particularly useful beside narrow garden paths, planting beds, and secondary routes where taller fixtures would be visually intrusive.
Their limited mounting height can restrict coverage. Depending on the optics, a fixture may illuminate the ground immediately around it while leaving darker areas between installation points.
For wider paths, increasing lumen output does not necessarily resolve this problem. A different optical distribution or mounting arrangement may provide better coverage.
Best suited to: Narrow landscaped routes where localized illumination and discreet fixture placement are priorities.
Less suitable for: Wide pedestrian routes requiring continuous illumination that the selected optics cannot provide.
Recessed Step, Wall, and In-Ground Lights
Recessed fixtures provide illumination without occupying space along a pedestrian route.
Step lights can illuminate stair treads and changes in elevation, while wall-integrated fixtures can direct light onto adjacent walking surfaces.
In-ground fixtures require a separate functional distinction.
An upward-facing fixture may illuminate a tree, column, or façade, while a different recessed design may provide localized path-edge illumination. Neither function should be assumed from the product’s appearance alone.
Installation details can determine long-term reliability. Recessed fixtures may require coordinated drainage, suitable cable connections, protection against surface loads, and access for replacement.
For in-ground installations, the surrounding construction should prevent avoidable water accumulation and allow maintenance without unnecessary damage to finished surfaces.
Best suited to: Stairs, retaining walls, hardscape transitions, and selected landscape features.
Key limitation: Optical suitability and installation reliability must be evaluated separately.
Landscape Spotlights and Uplights
Landscape spotlights concentrate light on selected trees, sculptures, monuments, and architectural surfaces.
Beam angle, aiming direction, fixture-to-target distance, and the dimensions of the illuminated feature determine the result.
A narrow beam may emphasize a tree trunk or architectural detail. A wider beam may cover a larger surface but can increase spill light if poorly aimed.
For example, a spotlight aimed at a tree beside a walkway may make the tree prominent while leaving the walking surface insufficiently illuminated.
Adjustable mounting can accommodate changes in vegetation and future landscape maintenance.
Best suited to: Accent lighting where the target and beam direction can be controlled.
Key limitation: Accent illumination should not be treated as proof of adequate pathway visibility.
Solar Pathway Lights
Solar pathway lights can reduce installation work where extending electrical infrastructure would require extensive excavation.
Their suitability depends on whether the solar panel and battery can support the required lighting schedule during unfavorable operating periods.
Buyers should examine usable battery capacity, solar exposure, panel orientation, charging conditions, operating temperature, and control settings.
A fixture advertised with a particular maximum runtime may not achieve that duration under every seasonal or environmental condition.
Battery replacement, component availability, and maintenance access also affect lifecycle costs.
Best suited to: Remote or supplementary paths with suitable solar exposure and manageable operating requirements.
Key limitation: Continuously occupied routes require evidence that the system can maintain the necessary illumination throughout the required hours.
How Light Distribution Affects Pathway Visibility
Lumens measure the visible light emitted by a fixture. Illuminance, expressed in lux or foot-candles, describes how much light reaches a surface.
Two luminaires with the same lumen output can produce different pathway conditions because their optics distribute light differently.
Why Equal Lumens Can Produce Different Results
Consider two hypothetical pathway lights installed at the same height and producing identical lumen output.
Fixture A concentrates light directly below the luminaire. Fixture B distributes more light along the walkway.
Fixture A may provide strong localized illumination but leave darker areas between fixtures. Fixture B may achieve better continuity along the path.
The appropriate choice depends on walkway dimensions, spacing, and the required illumination pattern.
This comparison illustrates optical behavior rather than measured performance from specific products.
Illuminance, Uniformity, and Glare
A walkway may meet an average illuminance target while still containing areas with insufficient light.
Minimum illuminance and uniformity help identify these gaps.
| Evaluation Metric | What It Reveals | Design Implication |
|---|---|---|
| Average horizontal illuminance | Overall light reaching the walking surface | Checks the general illumination level |
| Minimum horizontal illuminance | Lowest calculated light level within the evaluation area | Identifies potentially underlit locations |
| Illuminance uniformity | Variation between brighter and darker areas | Helps evaluate continuity along the route |
| Vertical illuminance | Light reaching upright surfaces and objects | Relevant to signs, people, and pedestrian identification |
| Glare | Potential visual discomfort or reduced visibility from bright sources | Influences shielding, aiming, and fixture placement |
| Spill light | Light reaching unintended areas | Influences beam control and boundary conditions |
Uniformity ratios must be compared using the same definition. Average-to-minimum and maximum-to-minimum ratios describe different relationships.
The calculation grid, mounting conditions, and luminaire output settings must also be consistent when comparing alternatives.
When Vertical Illuminance Becomes Important
Horizontal illuminance describes light reaching the ground, but it does not fully describe visibility throughout the pedestrian environment.
At entrances, intersections, and security-sensitive locations, lighting may also need to illuminate signs, approaching pedestrians, and other upright objects.
A design with adequate ground illumination may therefore require supplementary lighting to address these vertical visual tasks.
How to Determine Pathway Light Spacing
Pathway light spacing depends on mounting height, optical distribution, walkway width, required illuminance, and surrounding conditions.
A fixed spacing recommendation cannot account for all combinations of these variables.
Increasing spacing may reduce fixture quantities but leave dark gaps. Reducing spacing may improve coverage in some layouts while increasing glare, energy consumption, and maintenance requirements.
A Five-Step Pathway Lighting Layout Method
Step 1 — Define the visual tasks
Separate primary routes, secondary paths, stairs, intersections, entrances, and landscape features.
Establish the applicable lighting criteria for each area before choosing fixture quantities.
Step 2 — Record the site geometry
Measure walkway widths, elevation changes, available mounting positions, and nearby surfaces.
Identify vegetation, walls, and other obstructions that may affect the intended distribution.
Step 3 — Select suitable optical configurations
Compare candidate luminaires using their mounting heights, distributions, output settings, and shielding.
Confirm that the available IES photometric files correspond to the actual products being considered.
Step 4 — Calculate the layout
Use suitable lighting design software with the correct fixture orientation, mounting height, output configuration, calculation surface, and relevant site obstructions.
Evaluate average and minimum illuminance, the specified uniformity measure, spill light, and glare using appropriate methods.
Step 5 — Refine and verify
Adjust fixture spacing, mounting positions, optical distributions, or output settings until the design meets its requirements.
After installation, inspect the lighting under nighttime operating conditions and perform field measurements where required.

Narrow Garden Path vs. Wide Campus Walkway
A narrow garden path may achieve suitable coverage using low-profile fixtures along one edge.
A wider campus walkway may require shielded bollards on both sides, different optical distributions, or supplementary lighting at a higher mounting position.
The appropriate arrangement depends on the calculated performance rather than a fixed spacing rule.
Low-Voltage, Line-Voltage, or Solar Landscape Lighting?
Power supply selection affects wiring requirements, electrical losses, controls, installation costs, and maintenance.
| Factor | Low-Voltage Lighting | Line-Voltage Lighting | Solar Lighting |
|---|---|---|---|
| Power source | Compatible transformer or power supply | Building electrical distribution | Solar panel and battery |
| Typical use | Distributed path and accent fixtures | Permanently wired commercial luminaires | Remote or supplementary areas |
| Main design concern | Cable sizing, voltage drop, power supply capacity | Wiring methods, circuit protection, electrical compliance | Energy collection and storage |
| Maintenance focus | Connections, cables, power supplies | Drivers, enclosures, electrical connections | Batteries, panels, controllers |
| Main advantage | Flexible distribution of compatible fixtures | Integration with existing electrical infrastructure | Reduced need for trenching |
| Main limitation | Long cable runs require careful electrical design | Installation may involve more extensive electrical work | Runtime depends on stored energy |
Low-Voltage Lighting
Low-voltage systems are often used for distributed path and accent lighting.
For long cable runs, conductor resistance and connected loads can reduce the voltage available at individual fixtures.
In multi-fixture circuits, voltage drop should be evaluated by cable segment because the current flowing through each section may differ.
The most unfavorable fixture must still receive voltage within its specified operating range.
Line-Voltage Lighting
Line-voltage fixtures can integrate with permanent commercial electrical infrastructure.
Their installation requires appropriate wiring methods, circuit protection, grounding or bonding where applicable, and environmental protection.
The selected equipment and installation must comply with applicable electrical codes and manufacturer instructions.
Supply voltage alone does not determine energy efficiency. Luminaire efficacy, driver losses, wiring losses, and operating schedules affect total system consumption.
Solar Lighting
Solar system sizing should compare expected nighttime energy consumption with usable battery capacity and realistic charging conditions.
Short winter days, shading, and temperature-related battery limitations can reduce available energy.
Dimming or occupancy controls may reduce consumption where appropriate, but the operating schedule must still meet the site’s visibility requirements.
For continuously occupied routes, system performance should be assessed under unfavorable seasonal conditions rather than ideal charging conditions alone.
Common Landscape Lighting Selection Mistakes
The following mistakes can cause problems even when the selected luminaires appear suitable on a product specification sheet.
| Selection Mistake | Possible Consequence | Better Approach |
|---|---|---|
| Choosing fixtures by lumens alone | Bright areas near fixtures with dark gaps between them | Compare actual optical distributions and minimum illuminance |
| Applying one spacing rule to every path | Uneven coverage across different walkway widths | Use site geometry and IES-based calculations |
| Using uplights as pathway lighting | Landscape features appear bright while walking surfaces remain underlit | Separate accent and functional lighting |
| Selecting fixtures only by IP rating | Drainage, corrosion, or cable-entry problems remain unresolved | Evaluate complete construction and installation conditions |
| Ignoring pedestrian-level glare | Adequate ground illuminance but uncomfortable direct brightness | Review shielding, aiming, and source visibility |
| Comparing purchase price alone | Higher replacement and maintenance costs | Compare serviceability, spare parts, and lifecycle requirements |
| Assuming constant solar runtime | Reduced operation during unfavorable seasons | Verify seasonal energy balance and battery capacity |
What Makes Outdoor Landscape Lighting Durable?
Outdoor landscape fixtures may experience irrigation, rain, dust, ultraviolet exposure, temperature changes, and physical contact.
In-ground fixtures also face possible standing water, soil moisture, surface loading, and restricted maintenance access.
These exposures should determine which protection features and construction details require verification.
Understanding IP Ratings
Ingress Protection ratings describe resistance to solid objects and water under defined test conditions.
| IP Rating | Protection Described | Selection Consideration |
|---|---|---|
| IP65 | Dust-tight and protected against water jets | Fixtures exposed to rain and irrigation |
| IP66 | Dust-tight and protected against powerful water jets | Locations with more demanding water-jet exposure |
| IP67 | Dust-tight and protected against temporary immersion under defined conditions | Locations where temporary immersion may occur |
| IP68 | Dust-tight and protected against immersion under manufacturer-specified conditions | Applications requiring verification of immersion depth and duration |
The second digit is not a universal progression in which every higher rating automatically establishes all lower water-exposure tests.
For example, IP67 does not independently prove IP66 powerful water-jet resistance unless that protection has also been verified.
An IP68 rating must be interpreted according to the manufacturer’s specified immersion conditions.
For permanently submerged installations, verify the product’s intended use, electrical safety requirements, and installation conditions separately from its IP rating.
Housing Materials and Corrosion
Housing materials should be selected according to the environmental exposure and complete product construction.
Aluminum, stainless steel, brass, and other materials differ in mechanical properties, weight, cost, and corrosion behavior.
Protective coatings, fasteners, and material compatibility can be particularly important in coastal environments.
Where dissimilar metals are exposed to moisture, galvanic corrosion may also need consideration.
Review the relevant construction and corrosion-test documentation rather than relying solely on the material name.
Seals, Cable Entries, and Drainage
Water may enter through damaged gaskets, unsuitable cable glands, poorly secured connectors, or installation interfaces.
Repeated temperature changes can also affect sealing components over time.
For recessed and in-ground fixtures, drainage should be planned as part of the surrounding construction rather than assumed from the luminaire’s IP rating.
Service access should allow inspection and replacement without unnecessary damage to the finished landscape.

Thermal Management and LED Lifetime
LED performance depends partly on the temperature of the light source and associated electrical components.
Housing design, heat sinks, thermal interfaces, driver placement, and ambient temperature influence operating conditions.
Excessive heat can accelerate lumen depreciation and contribute to component failure.
LM-80 provides measured lumen-maintenance data for applicable LED packages, arrays, or modules. TM-21 provides a method for projecting lumen maintenance from suitable test data.
Neither establishes the service life of the complete outdoor luminaire.
Drivers, seals, connectors, and housings may require maintenance or replacement before the LED source reaches its projected lumen-maintenance threshold.
Buyers should therefore review ambient temperature ratings, warranty conditions, driver accessibility, and replacement component availability.
Color Temperature, Glare, and Light Pollution
Choosing Color Temperature
Warm white light around 2700K to 3000K is often suitable for landscaped courtyards, gardens, and hospitality environments.
It can complement natural materials without creating an unnecessarily cool visual appearance.
Other color temperatures may be appropriate when the visual task, surrounding lighting, or architectural design requires them.
In environmentally sensitive locations, lower correlated color temperatures or more carefully controlled spectral distributions may be preferable, subject to project requirements.
Color rendering also matters when illuminating vegetation, artwork, stone, and architectural finishes.
CRI provides a general indication of color rendering but does not describe every aspect of color appearance.
Controlling Glare and Unwanted Light
Glare depends on more than the amount of light reaching the ground.
A luminaire may provide adequate horizontal illuminance while exposing pedestrians to an uncomfortably bright light source.
Shielding, mounting position, beam direction, and source luminance should therefore be evaluated together.
Fixtures should illuminate the intended walking surface or landscape feature while limiting unnecessary light toward windows, neighboring properties, and the sky.
For uplighting, beam direction and target dimensions should be coordinated to reduce light escaping beyond the illuminated feature.
Using Lighting Controls
Photocells can respond to daylight conditions, while timers establish operating schedules.
Dimming and occupancy-based controls may reduce energy use during periods of lower activity.
However, reduced-output settings must still satisfy the visibility and accessibility requirements of occupied routes.
Separating pathway lighting from decorative and architectural lighting into control groups allows different operating schedules without unnecessarily reducing functional illumination.
Choosing Lighting Combinations for Commercial Sites
Commercial landscapes frequently require more than one fixture type because pedestrian routes, stairs, entrances, and architectural features serve different visual functions.
For commercial building lighting, pathway illumination should be coordinated with entrance and façade lighting so that brightness transitions do not create unnecessary visual discomfort.
| Commercial Site | Recommended Lighting Combination | Main Design Consideration |
|---|---|---|
| Office parks | Shielded bollards for routes, recessed lights at steps, selective accent lighting | Maintain pedestrian visibility without excessive landscape brightness |
| Hotels and resorts | Low-profile path lights, step lights, controlled feature lighting | Coordinate wayfinding with landscape appearance |
| University campuses | Route lighting with supplementary illumination at intersections and entrances | Address pedestrian identification and route continuity |
| Retail developments | Walkway lighting combined with entrance and façade lighting | Manage brightness transitions between parking areas and entrances |
| Public gardens | Low-level path lighting with carefully aimed accents | Limit unnecessary light beyond paths and selected features |
| Commercial building entrances | Wall-mounted or recessed lighting supplemented by bollards where appropriate | Illuminate changes in elevation and building approaches |
Example — Coordinating Lighting Across an Office Park
Consider an office park with a pedestrian route connecting parking areas, landscaped courtyards, and building entrances.
Shielded bollards could provide illumination along the primary route, while recessed step lights address changes in elevation. Adjustable spotlights could illuminate selected trees without relying on those accents to light the walkway.
At the transition between parking lot lighting and pedestrian-scale pathway lighting, differences in mounting height, illuminance, and optical distribution should be evaluated together. Security-sensitive locations may also require additional illumination to improve visibility of pedestrians and surrounding objects.
The design should then be checked using the actual photometric files, site geometry, and applicable lighting criteria.
This is an illustrative design scenario, not a measured installation or completed project.
What Should B2B Buyers Check Before Ordering?
Commercial landscape lighting procurement should verify that the proposed products match the design assumptions and can be maintained throughout the expected project life.
| Procurement Item | What to Verify | Why It Matters |
|---|---|---|
| IES photometric files | Exact model, optical configuration, output, and mounting assumptions | Supports valid lighting calculations |
| Electrical specifications | Input voltage, driver characteristics, control compatibility | Reduces system integration problems |
| Environmental suitability | IP rating, ambient temperature range, corrosion protection | Matches fixtures to site exposure |
| Safety documentation | Applicable listing or certification for the exact configuration | Supports compliance verification |
| Mechanical construction | Mounting hardware, cable entries, fasteners, impact exposure | Influences installation and durability |
| Product consistency | CCT tolerance, finish, optics, model identification | Supports consistency across installation phases |
| Maintenance provisions | Driver access, spare parts, warranty conditions | Affects replacement and service costs |
| Supply capability | Lead times, repeat-order availability, customization requirements | Supports project schedules and future replacements |
Confirming Applicable Safety Standards
The applicable safety standard depends on the luminaire’s construction, intended use, and electrical configuration.
UL 1838 addresses low-voltage landscape lighting systems and components within its defined scope.
UL 2108 covers low-voltage lighting systems and components within its defined scope.
UL 1598 may apply to certain other luminaire configurations, depending on their construction and intended use.
These standards are not interchangeable certifications, and not every outdoor fixture is required to comply with all of them.
Buyers should request documentation confirming which standard applies and whether the selected model and configuration are covered.
The installation must also meet applicable electrical codes and local requirements.
Comparing Landscape Lighting Manufacturers and Suppliers
Supplier comparisons should use equivalent technical and commercial conditions.
Two fixtures with similar wattage or lumen output may differ in optical distribution, driver characteristics, environmental protection, and serviceability.
Before comparing prices, confirm the following.
- Photometric equivalence: Do the IES files correspond to the actual optical and output configurations being offered?
- Electrical compatibility: Can each fixture operate with the specified supply voltage and control system?
- Environmental suitability: Are the materials and protection ratings appropriate for the installation?
- Certification scope: Do the available documents cover the exact models and configurations?
- Maintenance provisions: Are replacement drivers, connectors, and other service components available?
- Supply consistency: Can the supplier maintain the required specifications across future orders?
Where OEM or ODM customization is required, changes to optics, drivers, housings, or electrical configurations may affect testing, certification, lead times, and replacement compatibility.
A lower purchase price does not necessarily represent a lower project cost if the products require more frequent replacement or cannot maintain consistent specifications across installation phases.
Frequently Asked Questions
How many lumens do I need for pathway lighting?
There is no universal lumen requirement for every pathway light. The appropriate output depends on walkway width, mounting height, optical distribution, surrounding brightness, and required illuminance. A lower-output fixture with suitable optics may provide better usable coverage than a brighter fixture with poor distribution. Evaluate the complete layout rather than selecting products by lumens alone.
How far apart should commercial pathway lights be installed?
Spacing depends on mounting height, optical distribution, walkway dimensions, and project lighting criteria. Low-profile garden lights and taller bollards often require different layouts. Use the manufacturer’s photometric files to evaluate illuminance between fixtures, then refine the arrangement for uniformity, glare, and site constraints. Fixed spacing recommendations cannot replace project-specific calculations.
Are bollard lights better than low-profile path lights?
Bollards are often better suited to primary commercial walkways requiring broader pedestrian-scale illumination and durable permanent mounting. Low-profile path lights may be preferable in landscaped gardens where discreet appearance is important. The better choice depends on optical performance, glare, path width, installation conditions, and maintenance requirements rather than fixture category alone.
What IP rating is best for outdoor landscape lighting?
The appropriate IP rating depends on expected exposure. IP65 may suit many fixtures exposed to rain and irrigation, while locations with temporary immersion risks may require a differently rated product. Water-jet and immersion resistance are not automatically interchangeable. For in-ground or submerged installations, verify drainage, electrical connections, and the product’s specific suitability.
Are solar pathway lights suitable for commercial properties?
Solar pathway lights can suit remote or supplementary areas where electrical trenching is difficult. Their reliability depends on solar exposure, battery capacity, seasonal conditions, and required operating hours. For continuously occupied routes, verify performance during unfavorable periods. Wired lighting may be more appropriate when predictable illumination is essential throughout the night.
What color temperature is best for landscape and pathway lighting?
Warm white light around 2700K to 3000K is often appropriate for gardens, hospitality landscapes, and architectural surroundings. However, the best choice depends on visual tasks, adjacent lighting, environmental sensitivity, and local requirements. Color temperature should be considered alongside illuminance, color rendering, glare control, and the need to limit unnecessary short-wavelength light.
Conclusion
Select landscape and pathway lighting by defining the visual task, comparing suitable optical distributions, and validating the proposed layout against actual site conditions.
Before procurement, confirm environmental suitability, applicable certifications, maintenance requirements, and supplier consistency using documentation for the exact products being ordered.
For projects combining pedestrian routes and landscape features, functional pathway lighting and accent lighting should be evaluated as separate but coordinated parts of the overall design.