Commercial Office Lighting

LED Architectural Linear Lights provide clean, continuous illumination for offices, retail stores, hotels, schools, conference rooms, and other modern commercial interiors. Their sleek linear design makes them ideal for spaces where both functional lighting and architectural aesthetics matter.

LS01
- Power: 24W–70W (Selectable)
- Lumens: Up to 9,100 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K (Selectable)
- Beam Angle: 95°
- Mount: Suspension / Ceiling
- Dimming: 0–10V
LED Circular Downlights provide comfortable, evenly distributed illumination for offices, retail stores, hotels, restaurants, schools, corridors, and other commercial interiors. Their low-profile recessed design blends cleanly into ceilings, making them ideal for spaces that require both functional lighting and a modern, unobtrusive appearance.

SS-DLC
- Power: 9W / 12W / 18W
- Lumens: 720 lm / 960 lm / 1,440 lm
- Voltage: AC120V
- CCT: 2700K / 3000K / 3500K / 4000K / 5000K (Tunable)
- Beam Angle: 110°
- Dimming: 10%–100% TRIAC / ELV
- Rating: Wet Location / IC Rated
LED T8 Tube Lights provide efficient, uniform illumination for offices, schools, retail stores, warehouses, workshops, parking garages, and other commercial spaces. They are well suited for general lighting and fluorescent tube replacement applications.

T8 Integrated Tube
- Power: 12W–72W
- Lumens: Up to 9,360 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K / 5700K / 6500K (Selectable)
- Beam Angle: 120°
- Installation: Surface Mount / Suspension
- Dimming: Non-Dimmable

T8 Type B
- Power: 10W–36W
- Lumens: Up to 4,860 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K / 5700K / 6500K
- Beam Angle: 120°
- Installation: Type B / Single-End Wiring
- Dimming: Non-Dimmable
LED Panel Lights provide clean, uniform illumination for offices, schools, hospitals, retail stores, supermarkets, conference rooms, and other commercial interiors. Their slim, low-profile design works well for new construction and retrofit projects, delivering comfortable general lighting with a clean ceiling appearance.

BPL
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: DLC 6.0 Premium/ETL.
- Recommended Use: New construction or remodel, Office, Schools, Healthcare facilities, Institutions and commercial applications.
- Distribution: 120°.
LED Troffer Lights provide efficient, uniform illumination for offices, schools, hospitals, banks, retail stores, and other commercial and institutional spaces. Their recessed-style design integrates neatly with ceiling systems, making them well suited for both new construction and retrofit projects where comfortable general lighting and a clean ceiling appearance are required.

TRF14
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: ETL/DLC 6.0 Premium.
- Recommended Use: School, office, hospitality, education, bank, healthcare and more.
- Distribution: 120°.
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Commercial office lighting must balance work-plane illuminance, visual comfort, glare control, color quality, spatial brightness, and energy use across spaces with different visual tasks.
STARLAKE provides LED office lighting solutions for open-plan workspaces, private offices, conference rooms, reception areas, corridors, and collaborative spaces. Recessed, ceiling-mounted, and suspended options support conventional ceiling grids and architectural interiors, while 0–10V dimming is available across key office lighting families.
For distributors, contractors, designers, and project buyers, fixture selection should focus on delivering useful light where people work rather than maximizing lumen output.
Office Lighting Is More Than Lumens
Two luminaires with similar lumen output can produce different results because total luminous flux does not indicate where light reaches, how evenly it covers workstations, how bright the source appears within an employee’s field of view, or how much light reaches vertical surfaces.
A commercial office lighting layout should therefore balance:
Work-plane illuminance
Light distribution and uniformity
Direct and reflected glare
Ceiling and mounting height
Fixture spacing
Vertical surface illumination
Room geometry and reflectance
Daylight contribution
Increasing output without appropriate optics and layout can increase source brightness without proportionally improving useful illumination.
Vertical Light Changes How Bright an Office Feels
Desk-level illuminance describes only part of the visual environment. Walls, partitions, faces, whiteboards, shelving, and other vertical surfaces contribute to perceived spatial brightness.
An office with moderate horizontal illuminance and well-lit vertical surfaces can appear brighter and more open than one with higher desk-level illuminance but dark walls.
Vertical illumination is particularly relevant in reception areas, conference rooms, collaborative spaces, and executive offices where both task visibility and overall spatial appearance matter.
Use Task and Ambient Lighting for Modern Workspaces
A task-and-ambient strategy separates general illumination from the additional light required for more demanding visual work.
Instead of illuminating an entire floor to the highest level required by any individual activity, ambient lighting provides general illumination while additional light is concentrated where tasks require it.
Computer work, document review, technical drawings, meetings, presentations, circulation, and informal collaboration can have different lighting requirements. Separating these layers allows light levels to follow the visual task while avoiding unnecessary connected load in less demanding areas.
Match Lighting to Different Office Areas
Fixture type, distribution, color characteristics, and controls should follow the function of each office zone.
| Office Area | Main Lighting Priority | Typical Lighting Approach |
|---|---|---|
| Open-plan office | Uniformity and glare control | Panel, troffer, or linear lighting |
| Private office | Visual comfort and flexibility | General lighting with task or accent layers |
| Conference room | Multiple lighting scenes | Dimmable general lighting |
| Reception and lobby | Spatial brightness and presentation | General plus architectural lighting |
| Corridor and common area | Safe, efficient circulation | Controlled ambient lighting |
| Collaborative space | Flexible visual environment | Dimmable and layered lighting |
Open-Plan Offices
Open offices require consistent illumination across multiple workstations without excessively bright sources in common viewing directions.
Broad-distribution LED panels and troffers suit regular ceiling grids, while suspended linear luminaires can serve open ceilings and design-oriented interiors.
Fixture spacing should account for ceiling height, workstation orientation, partitions, daylight, and screen positions. Across long rows of desks, distribution and uniformity can be more important than maximizing individual fixture output.
STARLAKE office lighting families include broad-distribution panel and troffer configurations together with architectural linear options for suspended layouts.
Conference and Meeting Rooms
Meeting rooms may alternate between document review, presentations, video conferencing, collaborative discussion, and informal meetings.
Dimmable general lighting provides a foundation for these changing conditions. Depending on compatible components and project requirements, occupancy sensing, daylight response, or scene presets can provide additional control.
Screen location and luminaire placement should be coordinated to limit distracting reflections and excessive brightness around displays.
Reception and Client-Facing Areas
Reception lighting must provide functional visibility while supporting the visual presentation of the workplace.
Illuminating walls, signage, materials, artwork, and architectural surfaces can increase perceived spatial brightness and depth without raising general ceiling illumination.
Combining ambient illumination with architectural or linear lighting therefore allows reception areas to be treated differently from workstation zones.
Control Glare and Screen Reflections
Office occupants repeatedly shift their vision between monitors, documents, colleagues, and illuminated surfaces, making both direct and reflected glare relevant to fixture selection and layout.
High-luminance LED sources can create excessive brightness in normal viewing directions or reflections on screens and glossy surfaces if optical control and placement are unsuitable.
Effective glare control requires coordination among:
Luminaire optics and diffusion
Source shielding
Fixture location
Mounting height
Workstation orientation
Screen position
Surface reflectance
Light distribution
Where a project specifies UGR or another glare criterion, performance should be evaluated using the selected luminaire’s photometric data and actual room geometry rather than fixture appearance alone.
Match Color Quality and Controls to the Workspace
CCT and CRI should follow the visual function of each office zone rather than one building-wide specification.
Neutral white ranges are commonly considered for general work areas, while other CCTs may suit reception areas, executive spaces, or specific visual environments. Higher color-rendering performance becomes more relevant for graphic design, material review, printing, architectural work, and other color-sensitive tasks.
Available CCT and CRI configurations should be confirmed for the selected luminaire.
Use Dimming Where Lighting Demand Changes
Daylight, occupancy, and activities change office lighting demand throughout the day.
STARLAKE offers 0–10V dimming on key panel, troffer, and architectural linear configurations, providing a basis for controllable office lighting.
Depending on compatible components and project architecture, controls may also include:
Occupancy or vacancy sensing
Daylight harvesting
Scheduled operation
Zone-based dimming
Scene presets
Centralized building controls
Perimeter luminaires, for example, can operate as a separate control zone so their output can be reduced when daylight already contributes sufficient illumination.
Driver compatibility, sensors, wiring, electrical design, and applicable energy-code requirements should be coordinated before final fixture specification.
Office Lighting for Retrofit and New Construction
Retrofit and new-construction projects require different specification approaches because existing layouts constrain fixture placement differently.
Fluorescent Office Retrofit
Many existing offices use fluorescent troffers or linear fluorescent systems. LED replacement can reduce connected load and maintenance requirements, but wattage equivalence alone does not establish suitable lighting performance.
Review the existing:
Fixture type and ceiling grid
Lamp and ballast configuration
Fixture spacing
Circuit voltage
Mounting method
Work-plane light levels
Glare and uniformity problems
Dimming and control requirements
Emergency-lighting requirements
Certification or rebate requirements
The replacement should maintain or improve useful illumination while correcting identified distribution, glare, uniformity, or control limitations.
Retrofit projects can also introduce dimming or zoning that was unavailable in the original fluorescent installation.
New Office Construction
New construction allows fixture placement to be coordinated directly with workstation locations, ceiling systems, daylight, circulation routes, partitions, and interior architecture.
Recessed panels and troffers integrate with conventional ceiling grids, while suspended architectural linear lighting can suit open ceilings and contemporary interiors.
Early coordination with HVAC diffusers, sprinklers, acoustic systems, structural elements, and furniture layouts reduces ceiling conflicts and late fixture relocation during installation.
How to Specify Commercial Office Lighting
A reliable specification begins with the space and visual task before an individual luminaire is selected.
1. Define the Space and Visual Tasks
Separate open workstations, private offices, conference rooms, reception areas, corridors, and other zones according to their actual use.
2. Establish the Required Light Levels
Determine suitable horizontal and vertical illumination for each task according to project requirements and applicable lighting guidance rather than assigning one universal illuminance value across the office.
3. Confirm Ceiling Height and Geometry
Document ceiling height, room dimensions, workstation locations, windows, partitions, and major obstructions because these variables directly affect fixture placement and spacing.
4. Select Fixture Type and Distribution
Choose recessed, ceiling-mounted, or suspended luminaires according to the ceiling system and architectural requirements, then evaluate their photometric distribution.
A useful design sequence is:
Ceiling height → fixture spacing → optical distribution → work-plane illuminance → uniformity
5. Confirm Color, Electrical, and Control Requirements
Specify CCT and CRI together with input voltage, dimming interface, sensors, emergency requirements, and control strategy.
STARLAKE office lighting families include configurations for common North American commercial voltage ranges, with exact options depending on the selected product.
6. Verify Certification and Photometric Performance
Confirm certification for the exact product and configuration rather than assuming all fixtures within a category carry identical approvals.
STARLAKE office lighting options include models with UL or ETL and DLC qualifications, depending on the product.
Final quantity and spacing should be verified using fixture-specific IES files or photometric simulation. Preliminary lumen calculations cannot fully account for optical distribution, reflectance, room geometry, partitions, and obstructions.
Why Office Lighting Buyers Work With STARLAKE
Commercial office programs require engineering support, manufacturing consistency, quality control, customization, and supply planning alongside fixture performance.
Founded in 2010, STARLAKE operates approximately 280,000 sq.ft of production space with manufacturing operations in Shenzhen and Cambodia. More than 50 engineers support optical, thermal, electrical, control, and mechanical development, while 30+ QC professionals support manufacturing quality control.
Bulk production orders undergo an 8-hour aging test before shipment to identify potential early electrical, driver, component, or assembly failures.
For lighting brands, distributors, importers, and project suppliers, STARLAKE provides OEM and ODM support including:
Electrical and driver configurations
Wattage and lumen options
CCT configurations
Optical and structural development
Controls integration
Private labeling
Packaging customization
Certification coordination
Prototype and validation support
STARLAKE also maintains U.S. warehouses in Ohio and California. Qualifying stocked products can use local inventory for shorter replenishment cycles, while factory-direct production supports larger-volume and customized programs.
This allows buyers to coordinate customization, inventory requirements, manufacturing volumes, and project delivery schedules through one supply program.
Plan Your Commercial Office Lighting Project
Commercial office lighting should match illuminance, distribution, glare control, color quality, mounting conditions, electrical requirements, and controls to the way each office zone is used.
For project evaluation, prepare:
Floor plan and room dimensions
Ceiling or mounting height
Workstation and furniture layout
Target illuminance or project lighting criteria
Input voltage
Dimming and control requirements
Required certifications
New construction or retrofit conditions
STARLAKE can use these inputs to evaluate fixture configurations and support photometric planning before final quantities and specifications are confirmed.





