LED Warehouse Lighting Solutions


UFO11
- Power: 100W–240W
- Lumens: Up to 36,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K / 5700K
- Beam: 90° / 110°
- Mount: Hook / Loop / Yoke
- Dimming: 0–10V

UFO12
- Power: 100W–240W
- Lumens: Up to 36,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K / 5700K
- Beam Angle: 90° / 110°
- Mount: Loop / Hook / Yoke
- Dimming: 0–10V

LHB06
- Power: 80W–400W
- Lumens: Up to 60,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3500K / 4000K / 5000K / 5700K
- Beam Angle: 90°
- Mount: Suspension / Chain / Ceiling
- Dimming: 0–10V

LHB07
- Power: 80W–300W
- Lumens: Up to 45,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3500K / 4000K / 5000K
- Beam Angle: 90°
- Mount: Suspension / Chain / Ceiling
- Dimming: 0–10V

LHB08 Linear LED High Bay Light
- Power: 80W–300W
- Efficacy: Up to 140 lm/W
- Voltage: AC120–277V / AC120–347V / AC277–480V
- CCT: 3000K / 3500K / 4000K / 4500K / 5000K / 5700K
- Beam Angle: 90°
- Dimming: 0–10V
- IP Rating: IP44 / Damp Location

SS-VT
- Power: 25W–100W (Selectable)
- Lumens: Up to 12,500 lm
- Voltage: 120–277V
- CCT: 3500K / 4000K / 5000K / 5700K / 6500K (Selectable)
- Beam Angle: 120°
- Installation: Surface / Suspension
- Dimming: 0–10V
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





STARLAKE provides LED warehouse lighting solutions for high-bay warehouses, storage facilities, distribution buildings, fulfillment centers, and manufacturing storage areas where mounting height, rack geometry, long operating hours, and material-handling traffic affect lighting performance.
A warehouse lighting system should deliver useful light to floors, work planes, rack faces, labels, and traffic routes while maintaining uniformity and controlling glare.
STARLAKE supports warehouse projects with UFO and linear LED high bays, vapor-tight lighting, multiple voltage configurations, 0–10V dimming, compatible controls, and OEM/ODM capabilities.
Warehouse Lighting Is More Than a Lumen Problem
Total lumen output does not indicate where the light reaches.
Without suitable optics, a high-output fixture can create excessive intensity directly beneath the luminaire while illumination falls between fixtures or along vertical rack surfaces.
Warehouse lighting should therefore evaluate:
Target illuminance
Mounting height
Rack height and aisle width
Horizontal and vertical illumination
Optical distribution
Fixture spacing and uniformity
Glare
Environmental conditions
Controls
Supply voltage
The objective is usable, controlled illumination throughout the working space, not maximum lumen output.
Design Around Warehouse Geometry
Two warehouses with the same ceiling height can require different layouts.
An open bulk-storage facility may need broad coverage across large floor areas, while a high-rack warehouse requires controlled aisle illumination and useful vertical light on storage surfaces.
A practical selection sequence is:
Visual task → Target illuminance → Mounting height → Rack geometry → Fixture type → Optical distribution → Lumen output → Spacing → Controls → Photometric verification
Open Storage and Staging Areas
Open warehouse floors, bulk-storage zones, staging areas, and general material-handling spaces typically require broad, consistent coverage.
UFO high bays provide a practical starting point because their compact form works well across open high-ceiling layouts.
The final optic should still reflect mounting height and spacing. Wider distributions can support broader coverage, while higher installations may require greater optical control to maintain work-plane illuminance.
High-Rack and Narrow-Aisle Warehouses
Tall racks change both horizontal and vertical lighting requirements.
Light directed toward rack tops may contribute little to aisle visibility, while inadequate vertical illumination can make labels, barcodes, cartons, and rack positions harder to identify.
Linear high bays often provide a useful starting point because their geometry aligns naturally with long aisles. Final selection should still follow photometric performance rather than fixture shape alone.
Dusty, Damp, and Lower-Ceiling Areas
Not every warehouse zone requires a high bay.
Loading areas, utility spaces, service corridors, lower ceilings, and locations exposed to dust or moisture may benefit from enclosed vapor-tight fixtures.
Environmental protection, mounting method, distribution, and maintenance access should be evaluated together.
Design for Usable Light, Not Peak Brightness
Warehouse employees and vehicles move continuously across floors, racks, aisles, packing areas, and circulation routes.
Lighting should therefore maintain usable visual conditions across the working area rather than concentrate output beneath individual fixtures.
Maintain Uniformity Between Fixtures
A warehouse can meet an average illuminance target while still containing poorly illuminated areas.
Excessive brightness beneath luminaires combined with darker areas between them creates repeated visual adaptation for employees and vehicle operators.
Correcting this condition generally requires coordinated optics and spacing rather than simply increasing wattage.
Illuminate Vertical Rack Faces
Warehouse workers read labels, scan barcodes, locate inventory, and identify positions on vertical storage surfaces.
Vertical illuminance therefore matters in rack-based warehouses, particularly in high-rack and picking-intensive facilities.
The layout should evaluate light reaching rack faces at different heights rather than relying only on horizontal floor measurements.
Control Glare Along Working Routes
High-output LED luminaires can create uncomfortable direct glare when high-luminance sources enter normal viewing directions.
This matters along forklift routes, picking aisles, packing stations, loading areas, and locations where workers look toward upper racks.
Optics, mounting height, spacing, and fixture position should place required light on working surfaces without creating unnecessary source brightness.
UFO vs. Linear High Bay for Warehouses
Use fixture geometry as an initial selection tool, then verify the choice photometrically.
| Warehouse Condition | Typical Starting Point | Selection Logic |
|---|---|---|
| Open warehouse floor | UFO high bay | Compact installation with broad area coverage |
| Bulk storage | UFO high bay | Suitable for open high-ceiling layouts |
| Long rack aisles | Linear high bay | Geometry aligns with aisle-oriented layouts |
| High-rack warehouse | Linear high bay | Supports rack and aisle layout planning |
| Mixed open and rack areas | UFO + linear high bay | Allows zone-specific optical approaches |
| Dusty or damp lower areas | Vapor-tight fixture | Enclosed construction for demanding environments |
Mounting height, spacing, distribution, rack geometry, and target illuminance should determine the final configuration.
Warehouse Lighting Specification Matrix
Each specification should correspond to an actual warehouse condition.
| Design Variable | Why It Matters | What to Confirm |
|---|---|---|
| Mounting height | Affects coverage and work-plane illuminance | Floor-to-fixture distance |
| Rack geometry | Changes aisle and vertical illumination | Rack height, aisle width, orientation |
| Lumen output | Determines available light | Required maintained illuminance |
| Optics | Controls where lumens are delivered | Beam angle or photometric distribution |
| Fixture spacing | Affects uniformity | Layout and obstruction conditions |
| CCT | Influences visual appearance | Project requirement, commonly 4000K or 5000K |
| CRI | Affects color identification | Storage vs. picking, packing, or inspection |
| Voltage | Determines driver configuration | 120–277V, 347V, or 480V requirements |
| Controls | Can reduce unnecessary runtime | 0–10V and project control strategy |
| Environment | Affects enclosure selection | Dust, moisture, ambient temperature |
| Certification | May affect compliance and rebates | Model-specific UL, ETL, or DLC requirements |
| Photometrics | Validates installed performance | Fixture-specific IES data |
The final specification should follow the warehouse rather than a universal wattage or mounting-height rule.
Match Output and Optics to Mounting Height
Higher mounting positions increase the distance between the luminaire and working plane, but higher wattage is not automatically the correct response.
Optical distribution determines how effectively available lumens reach the target area. An excessively narrow beam can produce high intensity beneath the fixture while leaving insufficient overlap between luminaires.
STARLAKE’s current warehouse-lighting families cover approximately 25W to 400W, with selected linear high-bay configurations reaching up to 60,000 lumens.
Beam options vary by product family. Final output and spacing should be verified with fixture-specific photometric data when project geometry is available.
Use Controls to Reduce Unnecessary Runtime
Not every warehouse aisle requires full output throughout operating hours.
STARLAKE warehouse-lighting platforms support 0–10V dimming depending on product configuration, allowing compatible controls to adjust output by occupancy, daylight, or operating zone.
Occupancy-Based Dimming
Low-traffic aisles can operate at reduced output and return to the required working level when employees or vehicles enter the zone.
This strategy can be particularly relevant where occupancy varies substantially between storage aisles.
Daylight Harvesting and Zoning
Warehouses with skylights, clerestories, or perimeter glazing may receive useful daylight during part of the day.
Receiving, storage, picking, packing, loading, and circulation zones may also operate on different schedules. Daylight-responsive control and zoning can reduce electric-lighting runtime while maintaining required task illumination.
Actual savings depend on occupancy, daylight availability, schedules, dimming levels, and control sequences.
Reliability Matters at High Mounting Heights
Servicing a failed high-bay fixture may require a lift, trained personnel, safety procedures, aisle closure, and coordination with warehouse operations.
Reliability therefore affects lifecycle cost and operational disruption.
High-output LED luminaires also require an effective thermal path:
LED junction → PCB or MCPCB → thermal interface → housing or heat-dissipation structure → surrounding air
Poor heat transfer can increase component temperature and accelerate lumen depreciation or electronic stress.
STARLAKE subjects bulk production orders to an eight-hour aging test before shipment. New products undergo 30 days of continuous 24/7 high-temperature testing during validation.
These procedures help identify early component, electrical, and assembly problems but do not replace long-term lumen-maintenance or product-specific performance data.
Retrofit Existing Warehouse Lighting by Delivered Light
Many warehouse retrofits replace metal-halide, high-pressure sodium, or fluorescent systems.
LED replacement should follow required maintained illumination and distribution rather than wattage equivalence.
Before specification, confirm:
Existing fixture and lamp type
Existing system wattage, including ballast consumption
Mounting height and fixture spacing
Rack and aisle geometry
Existing measured illuminance
Required target illuminance
Supply voltage
Operating hours and controls
Aged HID or fluorescent systems may already deliver substantially less useful light than their original ratings.
The replacement system should therefore be evaluated against actual facility requirements and verified photometrically where appropriate.
Warehouse Lighting ROI Example
Consider a hypothetical warehouse replacing 100 existing 400W fixtures with 100 150W LED fixtures, after the proposed LED layout has been photometrically verified.
| Example Retrofit | Existing System | Proposed LED |
|---|---|---|
| Fixture quantity | 100 | 100 |
| Fixture wattage | 400W | 150W |
| Annual operating hours | 5,000 | 5,000 |
| Annual energy use | 200,000 kWh | 75,000 kWh |
Preliminary annual energy reduction: 125,000 kWh
At an assumed electricity rate of $0.12/kWh:
Estimated annual electricity-cost reduction: $15,000
This demonstrates the calculation method rather than a guaranteed savings result.
Actual ROI depends on validated fixture configuration, electricity rates, installation costs, schedules, controls, maintenance, rebates, demand charges, and total project cost.
What STARLAKE Needs for a Warehouse Lighting Layout
Useful project information includes:
Warehouse length and width
Ceiling and fixture mounting height
Rack height
Aisle width and orientation
Existing fixture locations
Existing lamp or fixture wattage
Supply voltage
Target illuminance
Operating hours
Environmental conditions
Required controls
Floor plans or reflected ceiling plans
Facility photographs where available
For retrofits, existing light-level measurements help establish whether the project should maintain current illumination, reduce overlighting, or correct an underlit system.
From Warehouse Layout to Lighting Supply
A warehouse lighting project can follow a structured engineering process.
1. Review the Warehouse Layout
Review facility dimensions, mounting height, rack arrangement, aisles, existing fixtures, and environmental conditions.
2. Define the Lighting Requirements
Establish target illuminance, uniformity, vertical visibility, controls, voltage, and other project criteria.
3. Select the Fixture and Optics
Match UFO high bay, linear high bay, vapor-tight fixture, output, beam configuration, and electrical options to the application.
4. Verify the Photometric Layout
Use fixture-specific photometric data to evaluate spacing and delivered illumination before finalizing the specification.
5. Confirm Commercial Requirements
Review certification, customization, packaging, labeling, quantity, lead time, and inventory requirements.
6. Manufacture and Supply
Move the project into factory production or use available U.S. inventory for selected stocked configurations where appropriate.
Engineering and Manufacturing Support for Warehouse Lighting
Warehouse projects may require different wattages, drivers, optics, sensors, mounting hardware, voltage configurations, private labeling, packaging, or certification support.
STARLAKE has 50+ engineers covering LED integration, driver design, thermal management, optics, mechanical development, digital controls, and product reliability.
OEM and ODM support can include:
Wattage and lumen configurations
Optical requirements
Driver and voltage options
Sensor and control integration
Mechanical customization
Private labeling
Packaging customization
Certification coordination
Certification should be confirmed at the individual model level.
Founded in 2010, STARLAKE operates approximately 280,000 sq.ft of production space, employs 400+ people, and maintains manufacturing operations in Shenzhen and Cambodia. Its broader lighting operations have annual production capacity exceeding approximately 20 million units, supported by 30+ QC professionals.
This structure supports individual warehouse projects as well as recurring distributor, private-label, and multi-site lighting programs.
U.S. Inventory Support for Warehouse Projects
STARLAKE maintains warehouses in Ohio and California with local inventory and fulfillment support for selected stocked products.
U.S. inventory can support time-sensitive retrofits, phased installations, distributor replenishment, replacement requirements, and projects combining factory production with local stock.
Availability is SKU-specific and should be confirmed during quotation.
Build the Warehouse Lighting Plan Around the Work
Effective warehouse lighting puts the required light on floors, racks, labels, equipment, and working surfaces while maintaining uniformity, controlling glare, and operating reliably under actual facility conditions.
Start with mounting height, rack and aisle geometry, visual tasks, and target illuminance. Then determine fixture format, optics, output, spacing, controls, electrical configuration, and environmental requirements.
STARLAKE supports warehouse lighting projects with engineering, OEM/ODM development, manufacturing, quality control, and selected U.S. inventory.
Send STARLAKE your warehouse layout, mounting height, rack configuration, voltage, target light level, and control requirements to evaluate suitable fixture and optical configurations before quotation.