LED Area Lights for Commercial Outdoor Lighting

LED Area Light factory

AR07 LED Area Light

  • Power: 100W–500W
  • Lumens: Up to 75,000 lm
  • Voltage: 120–277V / 120–347V / 277–480V
  • CCT: 3000K / 4000K / 5000K (Selectable)
  • Distribution: Type II / Type III / Type IV / Type V
  • Mount: Slip Fitter / Trunnion / Arm
  • Dimming: 0–10V

AR11 LED Area Light

  • Power: Multiple Wattages Available
  • Lumens: Up to 150 lm/W
  • Voltage: 120–277V / 120–347V / 277–480V
  • CCT: 3000K / 4000K / 5000K (Tunable)
  • Distribution: Type II / III / IV / V
  • IP Rating: IP65
  • Dimming: Motion Sensor / Dimmable

PT-LD03 LED Area Light

  • Power: 30W–120W
  • Lumens: Up to 18,600 lm
  • Voltage: 100–277V AC
  • CCT: 3000K–5000K
  • Distribution: Type II (T2)
  • Mount: Pole Mount / Arm Mount
  • IP Rating: IP67

Product Categories

Contact Us

Please enable JavaScript in your browser to complete this form.

Why Choose StarLake

ADVANCED MANUFACTURING

Manufacturing Excellence Behind Every Lighting Solution

At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.

CERTIFICATION & COMPLIANCE

Certified for Performance, Safety, and Market Compliance

Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.

LOCAL DELIVERY ADVANTAGE

Less Waiting. More Inventory. Better Project Support.

Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.

Outdoor area lighting should be selected around site geometry, pole layout, distribution, and required illuminance rather than fixture wattage alone.

STARLAKE LED area lights combine configurable output, Type II–V optics, flexible mounting, voltage options, and lighting controls for parking lots, roadways, auto dealerships, campuses, walkways, building perimeters, and other commercial outdoor sites.

For lighting brands, distributors, contractors, importers, and project suppliers, STARLAKE also provides OEM/ODM engineering, manufacturing, quality control, and North American warehouse support.

How to Choose the Right LED Area Light

Total lumens describe available light, while spatial distribution determines where that light reaches the site. Fixtures with similar lumen output can therefore produce different illuminance and uniformity.

A practical selection process should consider five factors.

1. Site Geometry

Define the application and dimensions. Narrow roadways, open parking areas, perimeter positions, and pedestrian routes require different patterns of light.

2. Pole Height and Spacing

Mounting height and pole spacing affect output requirements, distribution, coverage, and uniformity. Higher wattage cannot compensate for unsuitable pole geometry or optics.

3. Illuminance and Distribution

Establish the required light level on the target surface, then select a distribution that directs available light toward that area.

4. Electrical, Mounting, and Controls

Confirm supply voltage, mounting interface, CCT, dimming, photocell, and sensor requirements before specifying the final configuration.

5. Photometric Verification

For project lighting, use fixture-specific photometric data with the actual site layout to evaluate coverage and expected light levels.

This sequence reduces the risk of overlighting, dark zones, wasted energy, and incompatible configurations.

Type II, III, IV or V: Match the Distribution to the Site

Secondary optics redistribute LED output into patterns suited to different site geometries.

STARLAKE area light configurations support Type II, Type III, Type IV, and Type V distributions.

DistributionLighting CharacteristicTypical Application
Type IILateral distribution for relatively narrow, elongated areasRoadways, drive lanes, narrow circulation areas
Type IIIForward asymmetric distribution with useful lateral coverageParking areas, drive areas, general site lighting
Type IVPrimarily forward distribution with limited backlightPerimeter poles, property boundaries, edge-mounted applications
Type VMore symmetrical distribution around the mounting positionOpen parking areas, central pole positions, general area lighting

There is no universal distribution for every site. A perimeter pole may require forward coverage with controlled backlight, while an interior pole in an open area may require illumination in several directions.

The objective is to match the photometric pattern to the area the pole actually serves.

Uniformity Matters as Much as Lumen Output

High total output or center intensity does not guarantee effective area illumination.

Poor distribution can produce bright zones near poles, dark areas between fixtures, excessive spill light, or inefficient spacing.

Installed performance depends on the interaction of:

Lumen Output + Optical Distribution + Mounting Height + Pole Spacing + Illuminance + Uniformity

Glare should also be evaluated because compact LED sources can produce high luminance within common viewing directions.

Fixture positioning and suitable optics should therefore be evaluated together rather than using lumen output as the primary performance measure.

Built for Project Flexibility

Outdoor projects differ in pole layouts, electrical systems, mounting conditions, and operating strategies.

ConfigurationWhy It Matters
Selectable WattageAllows output to be adjusted for different site conditions
Type II–V OpticsAdapts distribution to roadway, perimeter, and open-area layouts
Multiple Voltage OptionsSupports different commercial and industrial electrical systems
Flexible MountingAccommodates different poles, arms, tenons, and structural conditions
Dimming & Sensor OptionsSupports operating schedules and energy-management strategies

Available configurations vary by model. Final selection should follow the project’s optical, electrical, mechanical, and control requirements.

LED Area Lighting by Application

Different outdoor environments place different demands on distribution, pole position, and controls.

ApplicationKey Selection Considerations
Parking LotsUniformity, pole spacing, pedestrian and vehicle visibility, Type III/V distribution
Roadways & Drive AreasDirectional coverage, roadway width, pole spacing, controlled forward throw
Auto DealershipsLot visibility, display-area coverage, perimeter conditions, nighttime operation
Campuses & WalkwaysPedestrian visibility, circulation routes, mounting height, controls
Building PerimetersForward distribution, boundary conditions, backlight and spill-light control

These are starting directions rather than fixed optical specifications. Actual pole position, site geometry, mounting height, and target illuminance should determine the final distribution.

Smarter Outdoor Lighting With Controls

Depending on model and configuration, STARLAKE area lights support 0–10V dimming, photocell, and motion or occupancy sensing options.

Photocell → Automatic dusk-to-dawn operation
Motion / Occupancy Sensor → Reduced output during low-activity periods
0–10V Dimming → Integration with compatible dimming and control strategies

Controls reduce unnecessary full-output operating hours while allowing the required illumination to be restored when the site is in use.

Mounting Options for New Projects and Retrofits

Depending on product configuration, STARLAKE supports slip-fitters, square or round pole mounts, arm-mounted configurations, trunnions, and yokes.

Slip-fitters provide aiming flexibility, while direct pole or arm mounting supports defined pole layouts. Trunnions and yokes can serve alternative structural conditions or applications requiring additional adjustment.

For existing poles, confirm tenon or pole dimensions, mounting orientation, fixture position, and supply voltage before ordering.

Pole photographs and dimensions can also help identify mounting compatibility before installation.

Designed for Long-Term Outdoor Operation

Current STARLAKE area light designs use die-cast aluminum housings with UV-resistant powder-coated finishes and are specified for IP65 wet-location applications, with a published operating range of -40°F to 113°F (-40°C to 45°C).

Thermal performance depends on transferring heat from the LED assembly through the luminaire structure into the surrounding environment.

A simplified path is:

LED junction → PCB or MCPCB → thermal interface → die-cast aluminum structure → surrounding air

STARLAKE’s current area light specifications state LED junction temperature below 85°C under stated design conditions.

Environmental suitability should still be evaluated with sealing, corrosion exposure, ambient temperature, electrical conditions, and installation method rather than IP rating or thermal data alone.

Replacing HID Area Lights With LED

Metal halide and high-pressure sodium fixtures remain common retrofit targets in outdoor lighting.

LED conversion can reduce connected load, provide instant operation, support controls, and offer more flexible photometric distributions. Replacement selection, however, should follow required site performance rather than fixed wattage equivalence.

Evaluate:

  • Existing fixture and system wattage

  • Pole height and spacing

  • Site geometry

  • Required illuminance and uniformity

  • Existing and proposed distribution

  • Supply voltage

  • Mounting interface

  • Controls

The replacement should provide the required maintained illumination and distribution across the actual site rather than simply substitute a lower-wattage fixture.

OEM & ODM LED Area Light Solutions

STARLAKE supports lighting brands, distributors, importers, wholesalers, contractors, and project suppliers requiring standard or customized area-lighting programs.

OEM and ODM capabilities can include optics, wattage and electrical configurations, drivers, sensors, housing and finish requirements, private labeling, packaging, and project-specific development.

Different changes have different engineering consequences.

CustomizationPossible Project Impact
Optical DistributionPhotometric evaluation or validation
Driver / VoltageElectrical compatibility and testing
Sensors & ControlsControl compatibility and functional testing
Housing / StructureMechanical, tooling, or thermal evaluation
Branding / PackagingMOQ, packaging development, and lead time
Major Electrical ChangesPossible certification review or additional testing

STARLAKE’s 50+ engineers and 100+ technical patents support optical, thermal, electrical, structural, and manufacturability considerations during development.

Because customization can affect tooling, certification, MOQ, testing, cost, and lead time, these requirements should be defined early.

LED Area Light Manufacturing & Quality Control

Founded in 2010, STARLAKE operates approximately 280,000 sq.ft of production facilities with 400+ employees, with manufacturing operations in Asia and warehouse support in Ohio and California.

STARLAKE has 30+ QC professionals supporting production quality. Bulk orders undergo an 8-hour aging test before shipment, while new products undergo 30 days of continuous high-temperature testing during product validation.

These procedures help identify early electrical, component, thermal, and assembly issues. Aging and validation testing should not be interpreted as a direct simulation or guarantee of full service life.

The manufacturing structure supports individual projects as well as recurring commercial, distributor, and private-label area-lighting programs.

What We Need to Recommend the Right Area Light

For quotation or project evaluation, provide as much of the following information as possible:

  • Application and site type

  • Site plan or dimensions

  • Pole height and spacing

  • Existing fixture information for retrofit projects

  • Required illuminance or foot-candle target

  • Input voltage

  • Preferred CCT

  • Mounting configuration

  • Dimming, photocell, or sensor requirements

  • Required certifications

  • Estimated quantity

Where available, include a site plan, pole layout, existing fixture specification, or pole photographs.

STARLAKE can then evaluate output, optical distribution, mounting, electrical, and control configurations around the actual site rather than fixture wattage alone.

Send Your Project Requirements

Have any questions?

Feel free to contact us anytime - +86 139 0248 9327