Commercial LED Garage Canopy Lights


GP06 LED Canopy Light
- Power: 20W–100W (Selectable)
- Lumens: Up to 13,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K (Selectable)
- Beam Angle: 150°
- Mount: Surface / Round Pole
- Dimming: 0–10V

GP04 LED Parking Garage Canopy Light
- Power: 20W–100W (Selectable)
- Lumens: Up to 13,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K (Selectable)
- Beam Angle: 150°
- Mount: Surface / Round Pole
- Dimming: 0–10V
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Wide, Uniform Coverage for Low-Ceiling Parking Environments
STARLAKE LED Garage Canopy Lights are designed for parking garages, multi-level parking structures, covered driveways, entrances, and commercial canopies where low mounting heights, long operating hours, and changing traffic levels affect lighting requirements.
With selectable wattages from 20W to 100W, output up to 13,500 lumens, efficacy up to 135 lm/W, 3500K/4000K/5000K selectable CCT, and a 150° wide lighting angle, the range allows contractors, distributors, and project buyers to configure output around different parking zones.
20–100W Selectable | Up to 13,500 lm | Up to 135 lm/W | 150° Wide Distribution | 120–277V | 0–10V Dimming
Garage Lighting Is About Where the Lumens Go
Parking structures place luminaires relatively close to vehicles, pedestrians, columns, ramps, walls, and driving surfaces. Concentrated output can therefore create bright areas beneath fixtures while surrounding surfaces receive less illumination.
STARLAKE Garage Canopy Lights use a 150° wide lighting angle to spread illumination across parking bays, drive aisles, and circulation areas rather than concentrating output into a narrow beam.
Think Beyond Fixture Lumens
Garage lighting performance depends on the relationship between:
Lumen Output → Distribution → Mounting Height & Spacing → Surface Illuminance → Uniformity
These variables provide a more useful basis for layout decisions than fixture wattage or lumens alone.
Wide Distribution for Low-Ceiling Garage Lighting
Parking garages present a different optical problem from high-bay environments.
Drivers and pedestrians can pass close to ceiling-mounted luminaires. Concentrated intensity within normal viewing directions can increase visual discomfort, while strong bright-to-dark transitions can reduce visibility of vehicles, structural elements, and surrounding surfaces.
A 150° wide distribution spreads illumination outward across relatively low-ceiling parking environments.
This approach can suit:
Underground parking garages
Multi-level parking structures
Covered parking areas
Drive aisles and ramps
Commercial building entrances
Drive-through and vehicle canopies
Loading and service areas
The objective is broad usable illumination across the space rather than high intensity directly beneath the fixture.
Selectable Wattage and CCT Reduce SKU Complexity
Different zones within one parking facility may require different output.
STARLAKE Garage Canopy Lights provide field-selectable wattage configurations from 20W to 100W, depending on model.
| Selectable Wattage | Maximum Output | Efficacy |
|---|---|---|
| 40/30/20W | 5,200 lm | 130 lm/W |
| 80/60/40W | 10,400 lm | 130 lm/W |
| 100/80/60W | 13,000 lm | 130 lm/W |
| 100/80/60/40/30W | 13,500 lm | 135 lm/W |
Available configurations vary by model.
The range also provides 3500K / 4000K / 5000K selectable CCT, allowing light appearance to be selected according to the project during installation.
3500K provides a warmer appearance, 4000K a neutral commercial appearance, and 5000K a cooler appearance.
For distributors and contractors, selectable configurations have an additional inventory advantage:
Fewer Fixture Variants → Multiple Wattages & CCTs → Broader Project Coverage → Lower SKU Complexity
This can reduce the number of dedicated configurations required in inventory while providing additional flexibility during commissioning.
Built for Long-Hour Garage and Canopy Operation
Parking garage lighting frequently operates for extended periods, making thermal management and environmental suitability relevant to lifecycle performance.
Thermal Management for Long Operating Hours
Heat generated at the LED junction must move through the luminaire structure into the surrounding environment. Higher component temperatures can affect lumen maintenance and electronic reliability.
STARLAKE Garage Canopy Lights use die-cast aluminum construction and thermal management design. The GP04 platform targets an LED junction temperature below 85°C under specified conditions.
Key specifications include:
Rated Lifetime: >50,000 hours
Operating Temperature: -40°F to 113°F
Storage Temperature: -40°F to 158°F
Power Factor: >0.9
Driver Efficiency: >90%
Warranty: 5-year limited
These specifications should be confirmed for the individual model being selected.
Wet-Location Construction
Covered parking structures can still be exposed to moisture, airborne dust, road residue, vehicle contaminants, and temperature changes. Entrances and open-sided canopies may experience greater environmental exposure.
STARLAKE Garage Canopy Lights are specified for wet locations and use die-cast aluminum construction for enclosed garages and covered transitional environments.
Reduce Energy When the Garage Is Quiet
Garage traffic can vary substantially throughout the operating period, creating opportunities to reduce unnecessary full-output runtime.
STARLAKE Garage Canopy Lights support continuous 0–10V dimming, with optional sensing configurations depending on model. Available options can include microwave and PIR occupancy sensing.
A typical control sequence is:
Variable Occupancy → Sensor Detection → Output Adjustment → Required Light When Occupied
During low-traffic periods, compatible controls can maintain reduced output and increase illumination when vehicles or pedestrians enter the detection area.
This can be useful for overnight operation, secondary parking levels, and other intermittently occupied zones.
Energy performance therefore depends on both fixture efficacy and operating strategy.
Practical Retrofit for Existing Parking Facilities
Older parking structures may still use HID, fluorescent, or other legacy lighting systems.
LED replacement should be based on required illumination and installed distribution rather than a fixed wattage conversion.
STARLAKE Garage Canopy Lights operate on AC120–277V and support surface installation. Mounting-plate designs simplify positioning and electrical connection, while selected configurations also support rigid-conduit pendant installation.
A practical retrofit sequence is:
Existing Lighting → Mounting Condition → Required Illuminance → Distribution → LED Output → Controls
Existing fixture spacing, mounting conditions, voltage, and current lighting problems should be documented before selecting the replacement configuration.
Where LED Garage Canopy Lights Work Best
| Application | Primary Lighting Requirement |
|---|---|
| Underground Parking Garages | Broad coverage from relatively low mounting heights |
| Multi-Level Parking Structures | Consistent illumination across parking and circulation areas |
| Drive Aisles & Ramps | Continuous visibility along vehicle paths |
| Covered Entrances | Reliable illumination in transitional and wet-location environments |
| Commercial Canopies | Wide-area illumination beneath covered structures |
| Loading & Service Areas | Flexible output for different working conditions |
Selectable output and CCT allow one Garage Canopy Light platform to serve multiple zones without requiring a dedicated fixture configuration for every condition.
How to Select the Right LED Garage Canopy Light
Configuration should begin with the installation environment.
| What to Check | Why It Matters |
|---|---|
| Mounting Height & Fixture Spacing | Determines coverage and interaction between neighboring luminaires |
| Garage Layout & Obstructions | Columns, ramps, walls, and parking geometry affect usable illumination |
| Required Illuminance | Defines the light needed on driving and pedestrian surfaces |
| Photometric Distribution | Shows where luminaire output reaches |
| Wattage & CCT | Matches output and appearance to individual zones |
| Controls | Determines whether dimming or occupancy sensing can reduce full-output runtime |
| Final Lighting Layout | Confirms quantity, spacing, illuminance, and uniformity |
STARLAKE provides photometric information for Garage Canopy Light configurations to support project evaluation.
A practical engineering chain is:
Mounting → Spacing → Distribution → Illuminance → Uniformity → Controls
Why Source LED Garage Canopy Lights From STARLAKE?
Commercial garage-lighting programs may require repeatable product configurations, engineering support, quality control, customization, and supply beyond the individual fixture specification.
STARLAKE has specialized in commercial, industrial, and architectural LED lighting since 2010, supported by approximately 280,000 sq.ft of production space, 50+ engineers, 30+ QC personnel, and 100+ technical patents.
Engineering Support From Specification to Production
STARLAKE’s engineering capabilities cover optical design, thermal management, drivers, structural development, controls, and OEM/ODM customization.
For garage-lighting projects, engineering discussions can therefore include mounting conditions, photometric requirements, controls, and electrical configurations in addition to fixture output.
Quality Control Built Into Production
Bulk orders undergo an 8-hour aging test, while new products undergo 30-day, 24/7 high-temperature testing during product validation.
These processes support early-stage electrical, component, thermal, and assembly screening rather than replacing long-term performance data.
Flexible Supply for Distributors and Project Buyers
Selectable wattage and CCT can reduce SKU complexity, while OEM/ODM capabilities support customized configurations, branding, packaging, and project-specific development.
Asian Manufacturing + U.S. Inventory Support
STARLAKE operates manufacturing facilities in Shenzhen and Cambodia, supported by warehouses in Ohio and California.
Selected U.S.-stocked configurations can support local fulfillment and replenishment, while customized or volume programs can be supplied through factory production.
Availability should be confirmed by SKU and project.
Plan Your Garage Lighting Around the Space
The appropriate Garage Canopy Light is the configuration that delivers required illumination across the actual parking environment while matching mounting conditions, electrical requirements, controls, and long-term operating needs.
Send STARLAKE your layout, mounting height, existing lighting information, target light level, voltage, and control requirements.
STARLAKE can evaluate a suitable Garage Canopy Light configuration for the project.
Mounting Conditions → Lighting Requirement → Product Configuration → Project Solution





