GS05 LED Gas Station Canopy Light
- Housing: Die-cast aluminum housing with powder coat finish; Prismatic UV Resistant Glass Lampshade.
- Electrical: AC 120–277V / 120–347V / 277–480V input voltage; 0–10V dimming.
- Mounting: Surface mounting, round pole.
- Certification list: UL/DLC 6.0 Premium.
- Recommended Use: Gas Station.
- Distribution: 110°.
Specifications
| Part No | Power | Luminous Flux | CCT | Input Voltage |
|---|---|---|---|---|
| SS-GS0510-100W | 100W | 13500lm | 3500K / 4000K / 5000K / 5700K | AC120-277V / AC120-347V |
| SS-GS0515-150W | 150W | 20250lm | 3500K / 4000K / 5000K / 5700K | AC120-277V / AC120-347V |
| SS-GS0520-200W | 200W | 27000lm | 3500K / 4000K / 5000K / 5700K | AC120-277V / AC120-347V |
Dimensions

Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





STARLAKE LED gas station lights are designed for fuel station canopies, forecourts, service areas, and commercial retrofit projects where uniform illumination, reliable operation, and long operating hours affect fixture selection.
The GS05 LED Gas Station Canopy Light is available in 100W, 120W, 150W, 200W, and 240W, with direct ceiling and 3/4-inch NPT pendant mounting options for different canopy structures.
Fixture selection should follow canopy geometry, delivered illuminance, distribution, uniformity, glare, mounting, and electrical requirements rather than wattage alone.
100W–240W Options | Ceiling & 3/4″ NPT Mounting | OEM/ODM Support | North American Supply Support
GS05 LED Gas Station Canopy Light Options
The GS05 platform covers five wattage levels across two housing sizes.
| Power | Fixture Dimensions | Selection Consideration |
|---|---|---|
| 100W | Approx. 16.54 × 16.54 × 2.64 in. | Lower-output canopy requirements |
| 120W | Approx. 16.54 × 16.54 × 2.64 in. | Moderate commercial canopy applications |
| 150W | Approx. 16.54 × 16.54 × 2.64 in. | Higher output within the compact housing platform |
| 200W | Approx. 21.26 × 21.26 × 2.64 in. | Larger or higher-output canopy projects |
| 240W | Approx. 21.26 × 21.26 × 2.64 in. | Highest-output GS05 configuration |
These are product output options, not fixed mounting-height recommendations.
Final selection should consider canopy dimensions, mounting height, fixture spacing, required illuminance, optical distribution, fixture quantity, and existing lighting conditions.
Delivered Light Matters More Than Lumens Alone
Gas station canopy lighting must deliver useful illumination across fuel dispensers, pump islands, vehicle lanes, payment areas, and surrounding circulation zones.
A high-output fixture can still produce excessive intensity directly beneath the luminaire while leaving weaker illumination between fixtures or near canopy edges.
A useful relationship is:
Fixture Output + Distribution + Canopy Geometry + Spacing → Delivered Illuminance & Uniformity
The layout should evaluate:
Ground-level illuminance
Coverage around fuel dispensers
Mounting height
Fixture spacing
Uniformity across pump islands
Visibility around vehicles and equipment
Driver-facing glare
For projects with specified light levels or uniformity requirements, use fixture-specific photometric data to validate the proposed layout.
Uniform Illumination With Controlled Glare
A high illuminance reading beneath one fixture does not establish adequate performance across the forecourt.
Poor spacing or distribution can create alternating bright and dark areas around pump islands and vehicle lanes. Increasing wattage may intensify the bright zone without correcting those transitions.
Glare also requires particular attention because drivers may enter a brightly illuminated forecourt from a substantially darker roadway.
During that transition, excessive source brightness within normal viewing directions can make it harder to identify pedestrians, curbs, dispensers, equipment, and other vehicles.
The lighting system should therefore coordinate output, optics, fixture position, and spacing to provide useful coverage without relying on isolated high-intensity areas.
How to Select an LED Gas Station Light
Use the actual canopy conditions rather than starting from a wattage-equivalence chart.
Site → Performance Target → Layout → Output → Electrical Configuration → Verification
1. Site
Document canopy length, width, mounting height, pump-island positions, proposed fixture locations, and relevant structural conditions.
2. Performance Target
Define the required illumination for fueling, payment, vehicle circulation, and other relevant task areas according to the project specification and applicable requirements.
3. Layout
Evaluate fixture position, spacing, and optical distribution against the canopy and pump-island geometry.
4. Output
Compare the available 100W–240W GS05 configurations after the required lighting result is established.
Higher wattage should be selected only when the layout requires additional output.
5. Electrical Configuration
Confirm supply voltage, wiring, dimming requirements, mounting method, and installation clearance.
6. Verification
Where performance criteria are defined, verify the proposed layout with fixture-specific photometric data or an IES-based lighting calculation before final specification.
Color Quality and Nighttime Visibility
CCT and CRI affect how vehicles, pedestrians, equipment, pump interfaces, safety information, and surrounding surfaces appear at night.
Color quality should be evaluated as part of the complete lighting system. Higher CRI cannot compensate for poor uniformity or insufficient illumination, and a higher CCT is not automatically more suitable for every station.
Required CCT and CRI should therefore be confirmed for the selected GS05 configuration and project specification.
Commercial Canopy Reliability Starts With the Environment
Gas station canopy fixtures can operate for long hours while encountering moisture, dust, temperature variation, cleaning activity, and different exposure levels around canopy edges.
Evaluate:
Ingress protection
Ambient operating temperature
Housing and sealing
Moisture and dust exposure
Corrosion conditions
Driver protection
Thermal management
Mounting security
Maintenance access
Exposure can vary within the same canopy. A fixture near an open perimeter may experience different conditions from one installed farther inside the structure.
Environmental ratings should therefore be confirmed for the selected GS05 configuration and actual installation location.
Thermal Management Affects Long-Term Performance
High-output LEDs generate heat that must move from the semiconductor into the surrounding environment.
The thermal path is:
LED Junction → PCB / Thermal Interface → Luminaire Housing → Surrounding Air
Higher thermal resistance can increase junction temperature and affect lumen maintenance or component reliability.
This is relevant to fuel stations because fixtures may operate throughout much of the night or continuously at some sites.
STARLAKE’s engineering capabilities include thermal management, optics, power-supply design, mechanical development, controls, and LED integration, allowing these variables to be considered together during product development and customization.
A Better Approach to HID Canopy Retrofits
Metal halide and high-pressure sodium fixtures remain common retrofit targets in commercial canopy lighting.
LED replacement should not assume:
Existing HID Wattage = New LED Wattage
Instead, document:
Existing fixture and lamp type
Existing system wattage and ballast consumption
Fixture condition and age
Mounting height
Fixture spacing
Current or required light levels
Existing distribution
Supply voltage
Then follow:
Existing System → Required Performance → Canopy Geometry → Photometric Evaluation → LED Configuration
This approach evaluates the replacement according to installed lighting performance rather than nominal wattage equivalence.
Ceiling and 3/4-Inch NPT Pendant Mounting
GS05 supports two documented installation approaches.
Ceiling Mounting
GS05 can mount directly to the canopy structure.
The documented installation procedure includes fixing hardware and a safety rope as an additional retention point above active vehicle and pedestrian areas.
The mounting surface, fixing points, structural suitability, and applicable installation requirements should be verified before installation.
3/4-Inch NPT Pendant Mounting
GS05 also supports 3/4-inch NPT pendant installation.
The electrical connection passes through the stem before the fixture is secured, providing an alternative for canopy structures or retrofit conditions requiring suspended mounting.
Final installation should be coordinated with the actual canopy structure, clearance, and electrical layout.
Dimming and Lighting Control Integration
The supplied GS05 wiring documentation identifies:
Black — Line
White — Neutral
Green — Earth
Purple — Dim+
Pink — Dim-
Dedicated dimming conductors provide a basis for integration with a compatible control configuration.
The exact input voltage, driver, dimming protocol, and control compatibility should be confirmed before ordering.
Where a project requires scheduled dimming, daylight-responsive operation, or integration with another facility-control strategy, define those requirements during quotation so the electrical configuration can be reviewed before production.
Commercial Applications
GS05 LED gas station canopy lights are intended primarily for covered commercial applications including:
Gas station canopies
Fuel station forecourts
Convenience-store fueling areas
Covered vehicle service areas
Commercial service stations
Covered loading areas
Covered vehicle circulation zones
Suitability should follow actual mounting height, environmental exposure, visual tasks, canopy geometry, electrical conditions, and operating schedule rather than application name alone.
What Should You Send for a Gas Station Lighting Quote?
Providing project information early allows the fixture and layout requirements to be evaluated together.
| Project Information | Why It Matters |
|---|---|
| Canopy dimensions | Defines the illuminated area |
| Mounting height | Affects delivered illuminance and coverage |
| Fixture positions and quantity | Determines spacing and optical overlap |
| Required light level | Establishes the performance target |
| Existing lighting | Supports retrofit evaluation |
| Site voltage | Confirms electrical compatibility |
| Mounting method | Determines installation configuration |
| Dimming or controls | Determines driver and wiring requirements |
| Environmental conditions | Helps evaluate product suitability |
| Certification requirements | Supports market and project compliance |
| Order quantity | Supports production planning |
| Delivery destination | Supports logistics planning |
For retrofit or photometric projects, also provide a canopy drawing, existing fixture schedule, or available site-lighting information.
OEM and ODM Support for Lighting Brands and Distributors
STARLAKE supports standard commercial lighting orders and OEM/ODM gas station lighting programs for brands, distributors, importers, and regional wholesalers.
Depending on the project, customization can involve:
Optical configuration
Electrical requirements
Driver selection
Thermal design
Mechanical requirements
Lighting controls
Product labeling
Private-label programs
Packaging
Certification support
Changes to electrical design, construction, tooling, or certification can affect validation, MOQ, cost, and production schedules.
STARLAKE’s 50+ engineering team supports development across optics, thermal management, power supplies, mechanical design, controls, and LED integration.
Quality Control for Long-Term Commercial Programs
Gas station canopy fixtures are installed above active vehicle and pedestrian areas, making maintenance access more disruptive than for many indoor luminaires.
STARLAKE has 30+ quality-control professionals, while bulk production orders undergo an 8-hour aging test before shipment to support early electrical and assembly screening.
New products undergo 30 days of continuous high-temperature testing during product validation.
These procedures address specific early-stage risks rather than serving as a standalone lifetime guarantee. Long-term performance also depends on thermal design, component selection, electrical protection, manufacturing consistency, operating conditions, and installation.
STARLAKE’s manufacturing operations in Shenzhen and Cambodia support repeat commercial and distribution programs.
Supply Support for North American Buyers
STARLAKE combines Asian manufacturing with warehouse support in Ohio and California for North American customers.
This structure can support selected local inventory, replenishment requirements, and projects combining factory production with North American fulfillment.
STARLAKE also works with certification and compliance systems including UL, DLC, FCC, and ISO 9001.
These systems serve different purposes, and applicable certification should be confirmed for the exact GS05 configuration and target market.
One Product Platform for Different Commercial Buyers
Different buyers evaluate the GS05 platform through different project requirements.
Electrical contractors and project buyers focus on mounting, wiring, photometric suitability, documentation, and delivery.
Lighting distributors require repeatable configurations, replacement continuity, and supply support.
Lighting brands and importers may require private labeling, packaging, engineering changes, certification coordination, and repeat production.
GS05 combines 100W–240W configurations, ceiling and 3/4-inch NPT mounting, engineering support, OEM/ODM capability, quality control, and commercial supply support within one canopy-lighting platform.
Specify the Right LED Gas Station Light
The appropriate gas station canopy light is determined by the lighting delivered across the actual forecourt rather than fixture wattage alone.
Canopy Geometry → Mounting Height → Distribution → Illuminance → Uniformity → Glare → Electrical Requirements → Fixture Selection
STARLAKE GS05 provides 100W–240W commercial canopy-lighting configurations supported by engineering, manufacturing, quality control, OEM/ODM development, and selected North American supply capabilities.
Send your canopy layout, mounting height, site voltage, existing lighting information, required certifications, and project quantity to STARLAKE for product selection and quotation.