Iluminación hospitalaria


BPL Series
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: DLC 6.0 Premium/ETL.
- Recommended Use: New construction or remodel, Office, Schools, Healthcare facilities, Institutions and commercial applications.
- Distribution: 120°.

TRF14
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: ETL/DLC 6.0 Premium.
- Recommended Use: School, office, hospitality, education, bank, healthcare and more.
- Distribution: 120°.

SP05
- Housing: Stamping process heat sink to improve production efficiency.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling installation, Suspension rod.
- Certification list: UL/DLC 6.0 Premium.
- Recommended Use: Schools, hospitals, supermarkets, offices, warehouses.
- Distribution: 120°.

LS01
- Power: 24W–70W (Selectable)
- Lumens: Up to 9,100 lm
- Voltage: 120–277V / 120–347V
- CCT: 3500K / 4000K / 5000K (Selectable)
- Beam Angle: 95°
- Mount: Suspension / Ceiling
- Dimming: 0–10V
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Hospital lighting must support clinical work, patient comfort, safe circulation, and continuous facility operation. Patient rooms, exam rooms, corridors, nurse stations, and administrative areas create different visual and operational requirements.
Hospital LED lighting should therefore be selected according to the space and visual task. Illuminance, glare, color quality, distribution, controls, ceiling conditions, maintenance access, and project requirements all influence the final specification.
STARLAKE supports commercial healthcare lighting projects with configurable LED panel, troffer, and linear lighting solutions, including selectable output, selectable CCT, 0–10V dimming, and commercial electrical options on applicable models.
Why Hospital Lighting Requires a Different Approach
Hospitals combine spaces for examination, computer work, patient recovery, circulation, and continuous overnight operation.
Clinical staff require sufficient task visibility, while patients may spend extended periods viewing ceiling luminaires from a reclined position. Lighting must therefore balance visual performance, patient comfort, and operational efficiency, with criteria adjusted to each hospital area.
Lighting Requirements Across Hospital Areas
Divide the facility by room function, visual task, occupancy, and patient viewing conditions before selecting luminaires.
| Hospital Area | Primary Need | Lighting Priority | General Lighting Direction |
|---|---|---|---|
| Patient rooms | Care and rest | Low glare, flexible output, comfort | Diffused panel, troffer, or linear lighting |
| Pasillos | Safe circulation | Uniformity and controlled brightness | Linear or broad-distribution lighting |
| Nurse stations | Continuous staff work | Task visibility and glare control | Panel or linear lighting |
| Waiting areas | Comfort and orientation | Balanced ambient illumination | Panel or architectural linear lighting |
| Exam rooms | Clinical visibility | Color quality and task illumination | Project-specific general lighting |
| Administrative areas | Screen and document work | Visual comfort and controllability | Low-glare commercial lighting |
| Utility and support areas | Functional visibility | Reliability and efficiency | Practical general illumination |
These are selection directions rather than universal criteria. Final illuminance, uniformity, color quality, and other performance requirements should follow the applicable project specification.
Patient Rooms Need Lighting for Care and Rest
Patient rooms can support resting, reading, routine care, cleaning, nighttime observation, and examination, making one fixed lighting condition unsuitable for every activity.
A practical design separates comfortable ambient illumination from higher-output task or examination lighting. Reduced nighttime output can support observation and movement without unnecessarily illuminating the entire room.
Applicable STARLAKE panel, troffer, and linear configurations offer 0–10V dimming for compatible general-lighting systems.
Projects requiring tunable white, dynamic circadian programming, bedside controls, or nurse-call integration should identify these functions separately. Selectable CCT does not provide tunable-white or circadian operation by itself.
Corridor Lighting Should Consider the Patient’s View
Hospital corridors create a viewing condition that conventional commercial layouts can overlook.
Staff generally view ceiling luminaires while standing, while patients transported on beds may look almost directly toward them. A layout comfortable at standing eye level can therefore produce greater source brightness from a patient’s viewing angle.
Fixture position, diffusion, spacing, uniformity, and nighttime output should be evaluated together. Linear luminaires can suit directional or continuous layouts, while panels and troffers provide broad illumination in conventional ceiling systems.
The final choice should follow corridor geometry and photometric performance rather than fixture shape alone.
Clinical Areas Need More Than Higher Output
Clinical visibility depends on illuminance, color quality, glare, shadows, uniformity, and the location of the visual task.
Color-rendering requirements become more important where staff need to distinguish skin tones or other color-sensitive details and should be specified according to the clinical task.
General-purpose LED panels, troffers, and linear luminaires can serve appropriate healthcare spaces. Operating rooms, surgical areas, imaging rooms, behavioral-health units, and other specialized medical environments may require dedicated luminaires with additional medical, safety, hygiene, optical, or material requirements.
These applications should be specified separately from general hospital lighting.
Lighting Quality Goes Beyond Lumens
Useful hospital lighting depends on where light reaches, how evenly it is distributed, how occupants view the luminaires, and whether color quality suits the task.
CRI and CCT
CRI becomes particularly relevant where staff need to distinguish skin tones and other color-sensitive details. Required performance should follow the visual task rather than one hospital-wide value.
CCT affects the visual environment and can also vary by room function. Patient-oriented spaces may favor warmer or neutral light, while task-oriented spaces may use neutral to cooler white light.
Applicable STARLAKE general-lighting configurations include 3500K, 4000K, and 5000K options, with selectable CCT available on relevant models.
Selectable CCT establishes a predefined operating color after selection. Tunable-white systems dynamically change color temperature and require compatible luminaires, drivers, and controls.
Glare, Distribution, and Uniformity
Glare requires particular attention where patients view luminaires while reclined. Optical diffusion, source brightness, fixture position, spacing, and viewing angle all affect comfort.
Distribution determines how effectively output reaches the required surfaces. Two luminaires with similar lumen output can produce different results because optics, mounting height, room geometry, reflectance, and spacing change the installed light pattern.
A useful selection sequence is:
Target light level → room geometry → mounting height → distribution → lumen output → fixture spacing
Critical layouts should be verified with fixture-specific IES photometric data rather than assigning a fixed coverage area to each luminaire.
Dimming and Controls for 24/7 Operation
Hospitals have changing lighting demand across patient rooms, corridors, waiting areas, offices, and support spaces, while daylight contribution varies throughout the building.
Depending on the project, controls may include:
0–10V dimming
Occupancy sensing
Daylight-responsive control
Time scheduling
Reduced nighttime output
Local room control
Building-level control
Applicable STARLAKE products support 0–10V dimming for compatible commercial control strategies.
Requirements such as DALI, circadian control, patient bedside control, or integration with hospital systems should be identified before fixture selection because they can affect drivers, wiring, controls, and commissioning.
Planning a Hospital LED Retrofit
Legacy fluorescent troffers and linear fluorescent systems can often be replaced with LED systems to reduce connected load and routine relamping, but replacement should be based on required lighting performance rather than wattage equivalence.
Before selecting a retrofit fixture, verify:
Existing fixture type and wattage
Ceiling system and fixture dimensions
Mounting height and spacing
Current and required illumination
Input voltage and wiring
Existing controls
Required CCT and CRI
Emergency-lighting conditions
Annual operating hours
The proposed LED system should be evaluated against the actual space, including illuminance, distribution, controls, and color requirements.
Energy analysis should include fixture quantity, operating hours, electricity cost, controls, maintenance labor, installation cost, and applicable incentives.
In active hospitals, installation logistics add another constraint. Phased delivery, repeatable replacement specifications, product availability, and future replenishment can reduce disruption where work must be coordinated around patients, staff, equipment, and continuously occupied areas.
How to Specify Hospital Lighting
A practical specification should begin with the facility rather than a product model.
Divide the facility by room type and visual task
Establish required illuminance and lighting-quality criteria
Confirm ceiling type and mounting height
Identify patient viewing conditions and glare risks
Select the appropriate luminaire format
Determine the required light distribution
Estimate lumen output and fixture spacing
Define CRI and CCT requirements
Confirm voltage and electrical configuration
Define dimming and control requirements
Review environmental and cleaning conditions
Identify emergency-lighting requirements
Confirm applicable certification and code requirements
Review installation and maintenance access
Validate critical layouts with photometric data
Confirm quantity, availability, and delivery schedule
This sequence reduces the risk of selecting a luminaire that meets electrical requirements but does not suit the room’s visual, installation, or operational conditions.
What to Verify Before Ordering Hospital Lighting
Lighting brands, distributors, contractors, and project buyers should confirm the following before final product selection.
| Verify | Por qué es importante |
|---|---|
| Hospital area | Determines visual, comfort, and operating requirements |
| Dimensiones de la habitación | Affects fixture quantity and distribution |
| Ceiling system | Determines fixture format and mounting method |
| Altura de montaje | Affects illuminance and coverage |
| Target illuminance | Establishes the required lighting result |
| CRI and CCT | Affects color recognition and visual environment |
| Tensión de entrada | Prevents electrical incompatibility |
| Dimming and controls | Determines driver and wiring requirements |
| Emergency requirements | May require a separate configuration |
| Cleaning conditions | Can change fixture construction requirements |
| Certificación | Must match the project and jurisdiction |
| Quantity and schedule | Affects manufacturing, inventory, and delivery planning |
Room schedules, drawings, reflected ceiling plans, existing fixture information, and photometric criteria help determine whether a standard configuration is suitable or engineering review is required.
From Lighting Specification to Project Supply
Healthcare projects can require consistent configurations across multiple rooms, floors, SKUs, and construction or renovation phases.
STARLAKE has manufactured LED lighting since 2010, with manufacturing operations in Shenzhen and Cambodia and more than 50 engineering professionals covering optical design, power supplies, thermal management, mechanical engineering, controls, and LED integration.
Engineering and OEM/ODM Support
For applicable OEM and ODM programs, STARLAKE can support wattage and lumen configurations, CCT, optics, electrical requirements, controls, housing, labeling, packaging, and certification preparation.
This allows lighting brands and distributors to coordinate configurations across multiple healthcare-lighting SKUs while identifying requirements that need additional engineering before production.
Certification, control, hygiene, and application requirements should be confirmed for the selected product rather than assumed across the entire range.
Quality and North American Supply Support
Consistency becomes important when the same luminaire is installed across multiple rooms, floors, or project phases.
STARLAKE maintains more than 30 QC professionals. Bulk production orders undergo an 8-hour aging test, while new products receive 30-day continuous high-temperature testing during validation to identify potential component, driver, assembly, or manufacturing issues.
STARLAKE also operates U.S. warehouses in Ohio and California. Local inventory for selected products can support replenishment, replacement requirements, and phased deliveries.
Customized configurations and larger OEM/ODM programs may require factory production, so inventory status and lead time should be confirmed during quotation.
Build a Hospital Lighting Solution Around the Space
Effective hospital lighting should match visual tasks, patient viewing conditions, controls, maintenance, certification, and installation requirements to each part of the facility.
Patient rooms require flexibility and comfort, corridors need glare control from both standing and reclined viewing positions, and clinical spaces place greater emphasis on task visibility and color quality.
STARLAKE supports commercial healthcare lighting projects through configurable LED lighting, engineering coordination, OEM and ODM capabilities, manufacturing, quality control, and selected North American inventory.
Send STARLAKE your room schedules, drawings, ceiling conditions, existing fixture information, target light levels, electrical and control requirements, quantities, and delivery schedule. The team can evaluate suitable general-lighting configurations and identify requirements needing project-specific review.