PT01
- Power: 20W–150W (Selectable)
- Lumens: Up to 21,000 lm
- Voltage: 120–277V / 120–347V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Angle: 120°
- Mount: 3″ Post Top
- Dimming: 0–10V

PT02
- Power: 20W–120W (Selectable)
- Efficacy: 140 lm/W
- Voltage: AC120–277V / AC120–347V / AC277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Angle: 120°
- Dimming: 0–10V
- IP Rating: IP65

PT03
- Power: 30W–100W (Selectable)
- Efficacy: Up to 140 lm/W
- Voltage: AC120–277V / AC120–347V / AC277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Beam Angle: 360°
- Dimming: 0–10V
- Lifetime: Over 50,000 Hours

BD Series
- Power: 14W–24W (Selectable)
- Lumens: Up to 3,600 lm
- Voltage: 120–277V / 120–347V
- CCT: 3000K / 4000K / 5000K
- Beam Angle: 120°
- Mount: Bollard Base Mount
- IP Rating: IP65
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





STARLAKE provides LED walkway lighting solutions for commercial campuses, schools, parks, office complexes, building approaches, landscaped areas, and other outdoor pedestrian routes where visibility, visual comfort, and controlled distribution matter.
Effective walkway lighting helps pedestrians identify the path, recognize people and obstacles, and move between outdoor spaces without excessive glare, dark gaps, or spill light.
Fixture selection should account for path geometry, required illuminance, distribution, placement, spacing, CCT, environmental exposure, and surrounding ambient light rather than wattage or lumen output alone.
Walkway Lighting Should Guide People, Not Just Illuminate Pavement
Pedestrian lighting needs to support both the walking surface and the surrounding visual environment.
Horizontal illuminance helps reveal pavement conditions, path edges, elevation changes, and obstacles. Vertical illuminance contributes to recognition of people and objects ahead.
A walkway can therefore achieve adequate average pavement illuminance while providing poor recognition or uncomfortable bright-to-dark transitions.
A well-designed system balances:
Usable illuminance
Distribución de la luz
Uniformity
Pedestrian-level glare
Path and edge visibility
Vertical visibility
Spill-light control
Visual transitions between adjacent spaces
The objective is sufficient, well-distributed light for nighttime movement rather than maximum brightness.
Light Distribution Matters More Than Lumens Alone
Lumens measure total visible light output but do not indicate where that light reaches.
A high-output luminaire with concentrated distribution can create bright pools beneath fixtures and dark gaps between them, while lower output with better optical control may produce more continuous path illumination.
Lumen output, optics, mounting position, and spacing should therefore be evaluated as one system.
Avoid Bright Spots and Dark Gaps
Spacing depends on:
Photometric distribution
Fixture mounting height
Walkway width
Flujo luminoso
Iluminancia requerida
Reflectancia superficial
Landscaping and obstructions
Surrounding ambient light
Target uniformity
There is no reliable universal spacing rule for walkway bollards.
Where illuminance and uniformity are specified, final spacing should be checked with fixture-specific photometric data and an IES-based lighting calculation.
Control Glare at Pedestrian Eye Level
Glare requires particular attention with bollards and other low-mounted luminaires because the light source operates close to a pedestrian’s normal field of view.
A directly visible high-luminance source can cause discomfort even when pavement illuminance is adequate.
Effective optical design should balance source shielding, distribution, ground-level illumination, and luminaire brightness. This becomes particularly relevant around entrances, plazas, campus paths, seating areas, and parks where pedestrians approach fixtures from multiple directions.
If a route is inadequately illuminated, revised optics, placement, or spacing may improve visibility more effectively than simply increasing output.
Match the Lighting Strategy to the Application
Pedestrian routes can use similar fixture forms while requiring different lighting priorities.
| Solicitud | Main Priority | Practical Design Approach |
|---|---|---|
| Commercial and office walkways | Visibility and architectural consistency | Coordinate pedestrian lighting with entrances, façades, and surrounding exterior lights |
| Campus and school pathways | Route continuity and pedestrian recognition | Balance horizontal illumination with useful vertical visibility |
| Parks and landscaped paths | Comfort and limited spill light | Use restrained output and controlled distribution with warmer appearance where appropriate |
| Building approaches | Visual adaptation and wayfinding | Coordinate pathway, canopy, façade, and interior lighting |
| Pedestrian plazas | Visibility across wider areas | Determine whether bollards provide sufficient coverage or should work with higher-mounted luminaires |
Commercial properties often require continuous pedestrian connections between parking areas, entrances, office buildings, and plazas. Pathway lighting should therefore be coordinated with the surrounding exterior system.
Campus routes require additional attention at intersections, ramps, stairs, entrances, and changes in direction, where route continuity and recognition become particularly important.
Parks and landscaped paths can use more restrained illumination to define the route while limiting unnecessary light on vegetation and surrounding areas.
Building approaches should coordinate pathway, façade, canopy, and entrance lighting to manage the transition between outdoor and indoor environments.
Choose CCT for the Environment
There is no single CCT suitable for every walkway.
STARLAKE’s current BD LED Bollard Light configurations provide 3000K, 4000K, and 5000K options.
| CCT | Practical Project Consideration |
|---|---|
| 3000K | Parks, landscaped paths, hospitality environments, and projects preferring a warmer nighttime appearance |
| 4000K | Many campuses, commercial properties, and institutional pedestrian routes |
| 5000K | Projects specifically requiring a cooler appearance or coordination with surrounding lighting |
CCT should also be coordinated across pathways, façades, entrances, and adjacent exterior lighting to avoid visibly inconsistent nighttime environments.
Environmentally sensitive projects may additionally require limits on uplight, spectrum, light trespass, operating hours, or lighting zones.
A warm CCT alone does not make a luminaire Dark-Sky compliant.
Design for Outdoor Reliability
Outdoor walkway luminaires can be exposed to rain, dust, UV radiation, humidity, temperature variation, and repeated thermal cycling.
The current STARLAKE BD LED Bollard Light uses a die-cast aluminum housing with powder-coated finish, UV-stabilized polycarbonate lens, and IP65 construction. Available electrical configurations include AC 120–277V and AC 120–347V.
These features address enclosure protection, outdoor material exposure, and common commercial electrical requirements, but IP rating alone does not establish complete site suitability.
Project teams should also evaluate:
Temperatura ambiente
Rain and drainage
UV exposure
Corrosive conditions
Mechanical impact risk
Foundation and mounting conditions
Electrical surge exposure
Driver operating conditions
Maintenance access
Coastal locations, severe climates, high-impact areas, and chemically aggressive environments may require additional evaluation.
Select Output Around the Layout
The current STARLAKE bollard configuration provides selectable 14W, 19W, and 24W options with output up to 3,600 lumens.
Required output depends on walkway width, fixture spacing, distribution, ambient conditions, and target lighting performance. A narrow route with closer spacing may require less output than a wider pedestrian area.
A practical selection sequence is:
Lighting requirement → distribution → spacing → appropriate output
This avoids using additional connected load to compensate for unsuitable optics or fixture placement.
Use Controls Where They Add Project Value
Pedestrian traffic can change substantially throughout the night. Campus paths may be busiest after evening classes, while office walkways can experience concentrated traffic around shift changes.
Depending on the selected luminaire and control configuration, projects may consider photocells, scheduling, occupancy sensing, dimming, or curfew-based output reduction.
Control compatibility should be confirmed for the exact product configuration because driver interface, sensor type, dimming capability, and zoning requirements can vary.
A Six-Step Approach to Specifying Walkway Lighting
Professional selection should begin with the site rather than the fixture catalog.
1. Understand the Site
Identify walkway width and length, intersections, stairs, ramps, entrances, landscaping, surrounding buildings, existing lighting, and physical obstructions.
2. Define the Lighting Requirement
Determine what pedestrians need to see and establish applicable criteria for horizontal illuminance, vertical visibility, uniformity, and exterior lighting.
3. Select the Lighting Approach and Distribution
Determine whether bollards, pole-mounted luminaires, wall-mounted fixtures, or a combination best suits the site.
Then evaluate whether the proposed distribution illuminates the required pedestrian surfaces while controlling spill beyond them.
4. Determine Output and Spacing Together
Select output according to photometric distribution, mounting arrangement, walkway geometry, and target performance rather than applying a fixed wattage or spacing rule.
5. Confirm Electrical and Environmental Requirements
Verify input voltage, CCT, controls, enclosure protection, mounting conditions, environmental exposure, and required certifications.
Certification should be confirmed for the exact product configuration being purchased.
6. Validate the Layout
Where lighting performance is specified, verify illuminance and uniformity with fixture-specific photometric data and IES-based simulation.
Preliminary spacing estimates can support planning but should not replace photometric verification where performance is contractual.
Retrofit the Lighting Performance, Not Just the Wattage
Existing pedestrian routes may use HID or other conventional outdoor fixtures. LED retrofit selection should begin with existing fixture locations, mounting conditions, electrical systems, and lighting performance rather than a watt-for-watt replacement.
Better optical control may maintain or improve useful illumination with lower connected load. However, retaining an existing layout with poor spacing or distribution can reproduce the same uniformity problems after the retrofit.
Evaluate the existing layout and replacement photometrics together.
What to Provide for a Walkway Lighting Project
For project evaluation, useful information includes:
Site plan or walkway dimensions
Proposed fixture locations or quantity
Existing fixture information for retrofits
Required illuminance or project criteria
Mounting requirements
Preferred CCT
Tensión de entrada
Control requirements
Environmental conditions
Certificaciones necesarias
Project location
Quantity and delivery schedule
For performance-based projects, photometric requirements should be provided before the final product and layout are approved.
Engineering, Manufacturing, and Supply Support From STARLAKE
Walkway lighting programs can require coordination of optical performance, electrical configurations, manufacturing consistency, customization, quality control, and replenishment.
Engineering Support
Founded in 2010, STARLAKE supports commercial, industrial, outdoor, and architectural LED lighting programs.
Its 50+ engineering professionals cover optical design, thermal management, power supplies, mechanical engineering, digital controls, and LED integration.
For OEM and ODM programs, STARLAKE can support product configuration, structural development, optical solutions, driver and electrical options, CCT selection, private labeling, packaging, and certification coordination.
Manufacturing and Quality Control
STARLAKE operates manufacturing facilities in Shenzhen and Cambodia.
Bulk production orders undergo an eight-hour aging test, while new products undergo 30 days of continuous 24/7 high-temperature testing during product validation.
These processes help identify potential component, assembly, and thermal issues, while project-specific certification and performance requirements should still be confirmed for the selected product.
North American Supply Support
STARLAKE maintains warehouses in Ohio and California for selected U.S. inventory and North American fulfillment.
For recurring commercial projects and distribution programs, local inventory can support replenishment and replacement requirements, while factory production supports customized and larger-volume programs.
Build Your Walkway Lighting Solution Around the Site
Effective walkway lighting depends on delivering useful horizontal and vertical illumination while controlling glare, dark gaps, spill light, and unnecessary energy use.
Start with walkway geometry and visual requirements, then evaluate distribution, output, spacing, CCT, environmental protection, electrical requirements, controls, and certification. Use fixture-specific photometric data where final illuminance or uniformity must be verified.
STARLAKE supports lighting brands, distributors, contractors, importers, and project buyers with LED walkway lighting selection, OEM and ODM development, manufacturing, quality control, certification coordination, and selected North American inventory.
Send STARLAKE your site plan, walkway dimensions, lighting requirements, voltage, preferred CCT, project quantity, and delivery schedule for product selection and project evaluation.