Parking Lot Lighting Solution


AR07
- Power: 100W–500W
- Lumens: Up to 75,000 lm
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Selectable)
- Distribution: Type II / Type III / Type IV / Type V
- Mount: Slip Fitter / Trunnion / Arm
- Dimming: 0–10V

AR11
- Power: Multiple Wattages Available
- Lumens: Up to 150 lm/W
- Voltage: 120–277V / 120–347V / 277–480V
- CCT: 3000K / 4000K / 5000K (Tunable)
- Distribution: Type II / III / IV / V
- IP Rating: IP65
- Dimming: Motion Sensor / Dimmable

PT-LD03
- Power: 30W–120W
- Lumens: Up to 18,600 lm
- Voltage: 100–277V AC
- CCT: 3000K–5000K
- Distribution: Type II (T2)
- Mount: Pole Mount / Arm Mount
- IP Rating: IP67
Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





Good parking lot lighting distributes useful light across parking spaces, drive lanes, pedestrian routes, entrances, and property boundaries while controlling glare, dark zones, uplight, and wasted energy.
STARLAKE provides commercial LED parking lot lighting for new construction and HID retrofit projects. Our area lighting configurations support multiple lumen packages, Type II, III, IV, and V distributions, mounting options, voltage requirements, photocells, and dimming controls.
For shopping centers, office campuses, hospitals, hotels, logistics facilities, dealerships, and industrial properties, fixture selection should begin with site geometry, pole position, mounting height, target illuminance, distribution, spacing, and uniformity rather than wattage alone.
Good Parking Lot Lighting Starts With Photometric Distribution
Two LED parking lot lights with the same lumen output can produce different pavement conditions because their optical distributions place light differently.
Concentrated output can create a bright area beneath the pole followed by rapid illuminance decline between poles. Increasing wattage may intensify the hotspot without correcting darker areas.
Secondary optics should distribute available light across the intended parking and traffic surfaces while controlling intensity that contributes to glare, backlight, or uplight.
Parking lot lighting should therefore be evaluated through illuminance and photometric distribution rather than total fixture lumens alone.
Design for Uniformity, Not Just Brightness
Drivers and pedestrians move continuously between the coverage areas of multiple luminaires. Large illuminance differences require repeated visual adaptation and can reduce recognition of pedestrians, curbs, wheel stops, vehicles, and pavement markings.
A parking lot layout should evaluate:
Average illuminance
Minimum illuminance
Maximum illuminance
Uniformità
Coverage between adjacent fixtures
High-intensity zones
Perimeter spill light
Smooth overlap between neighboring luminaires is often more useful than very high illuminance directly beneath individual poles.
Final performance should be verified with fixture-specific photometric data and applicable project criteria.
Match Light Distribution to Pole Position
Perimeter poles, internal poles, roadway poles, and intersection locations require different distributions.
Type II
Type II provides narrower lateral distribution and can suit drive lanes, access roads, and other elongated areas where controlled forward coverage is required.
Type III
Type III provides broader lateral coverage and is commonly considered for parking rows and paved areas where light must extend across multiple parking spaces.
Type IV
Type IV emphasizes forward throw and can suit perimeter poles, building-side locations, and property edges where backlight behind the luminaire needs greater control.
Type V
Type V provides more symmetrical coverage around the mounting position and can suit interior poles serving broad open areas in several directions.
Distribution should follow pole location and site geometry rather than total parking-lot size.
Parking Lot Lighting Selection Guide
Use the following as an early selection reference. Final configurations should still be verified through project-specific photometric analysis.
| Project Condition | Starting Direction |
|---|---|
| Narrow drive lane or access road | Consider Type II |
| Parking rows and broad paved areas | Consider Type III |
| Perimeter or property-edge pole | Consider Type III or Type IV |
| Large open area with an interior pole | Consider Type V |
| Higher mounting position | Review lumen output and optical reach together |
| Residential property nearby | Prioritize controlled backlight and uplight |
| Existing HID retrofit | Verify pole spacing and existing light levels before selecting wattage |
| Low traffic during late-night hours | Consider dimming, photocell, or occupancy controls |
These are starting points rather than universal rules. Pole height, fixture orientation, surrounding luminaires, property boundaries, and required light levels can change the final selection.
Send STARLAKE your site plan, mounting height, pole spacing, and target light levels if you need help narrowing the optical and fixture configuration before quotation.
Control Glare Without Creating Dark Areas
High-output LEDs can produce uncomfortable source brightness when luminaires enter a driver’s normal field of view.
Optical design should control high-angle intensity while maintaining required pavement illumination, particularly around:
Parking lot entrances and exits
Internal intersections
Pedestrian crossings
Vehicle turning areas
Property boundaries
Adjacent roadways
Reducing wattage alone may lower pavement illuminance without correcting glare caused by unsuitable optics or fixture orientation. The design objective is controlled distribution rather than simply lower output.
Limit Uplight and Light Trespass
Outdoor light that misses its intended area can enter neighboring properties, illuminate windows, spill onto roads, or contribute to sky glow.
Parking lot layouts should direct light toward pavement and pedestrian surfaces while controlling uplight, high-angle intensity, and backlight near property boundaries.
Perimeter poles deserve particular attention because an optic suitable for an interior pole may send unwanted light behind the property line.
Where outdoor-lighting ordinances or dark-sky requirements apply, compliance should be evaluated using the specific luminaire configuration and photometric data rather than assumed from the product category.
Select Output by Mounting Height and Spacing
There is no universal parking lot light wattage for a given pole height. Output, distribution, mounting height, and fixture spacing jointly determine pavement illuminance and coverage.
A practical selection sequence is:
Define parking, traffic, and pedestrian areas.
Establish illuminance and uniformity targets.
Confirm pole locations.
Determine mounting height.
Select the appropriate distribution.
Estimate the required lumen package.
Check overlap between adjacent fixtures.
Review glare, backlight, and property-line conditions.
Verify the layout with fixture-specific IES files.
Adjust output, optics, orientation, or fixture quantity where necessary.
This sequence establishes the required lighting result before fixture wattage is finalized.
Choose CCT and CRI for the Application
Parking lot lighting should support recognition of vehicles, pedestrians, pavement markings, signs, and obstacles.
STARLAKE LED parking lot lighting configurations support common CCT options depending on the specific product.
| CCT | Typical Consideration |
|---|---|
| 3000K | Warmer appearance where environmental, architectural, or local requirements favor lower CCT |
| 4000K | Neutral-white appearance for many commercial sites |
| 5000K | Cooler-white appearance where required by the project or surrounding lighting environment |
Higher CCT should not automatically be treated as better. Surrounding conditions, visual requirements, and local regulations should guide selection.
CRI should also be considered where recognition of vehicles, clothing, signage, or other color information matters.
LED Parking Lot Lights Built for Outdoor Operation
Parking lot luminaires remain exposed to rain, dust, humidity, UV radiation, temperature changes, salt, and electrical disturbances throughout their service life.
Weather and Ingress Protection
STARLAKE parking lot lighting products include configurations with IP65 and IP67 protection, depending on the model.
IP rating should be evaluated alongside housing construction, sealing, coating, corrosion resistance, thermal performance, driver protection, and installation conditions.
Thermal Management
Heat generated at the LED package must move through the luminaire before dissipating into the surrounding air.
A simplified thermal path is:
LED package → PCB or MCPCB → aluminum housing or heat sink → surrounding air
Thermal-interface quality, housing geometry, LED drive current, ambient temperature, and available heat-dissipation area affect this process.
Effective thermal management helps control component temperature and support lumen maintenance and electronic reliability during long operating periods.
Surge Protection and Maintenance
Pole-mounted luminaires can experience transient voltages associated with switching events or lightning activity. Required surge protection depends on site exposure, electrical configuration, grounding, and project requirements.
Maintenance also carries a site cost. Servicing a pole-mounted fixture may require a lift truck, trained personnel, traffic management, and temporary closure of parking spaces.
Lifecycle evaluation should therefore consider thermal performance, drivers, surge protection, sealing, lumen maintenance, warranty support, and replacement availability alongside fixture price.
Use Controls to Reduce Unnecessary Energy Consumption
Parking lots often operate for long hours while traffic varies substantially through the night.
Depending on the project, control strategies may include:
Photocells for dusk-to-dawn operation
0–10V dimming
Motion or occupancy sensing
Time-based scheduling
Digital or centralized control systems
Photocells can prevent daytime operation, while dimming or occupancy strategies can reduce output during low-traffic periods.
Control design should account for security requirements, traffic patterns, operating hours, driver compatibility, and applicable energy codes.
Replacing Metal Halide and HPS Parking Lot Lights
Metal halide and high-pressure sodium systems remain common retrofit targets in existing parking facilities.
LED conversion can reduce connected load, eliminate lamp warm-up, support electronic controls, and provide more flexible optical distributions. Replacement configuration, however, should follow site performance rather than wattage equivalence.
Before selecting an LED replacement, document:
Existing lamp and ballast wattage
Pole height and spacing
Existing fixture condition
Existing and required light levels
Current distribution pattern
Electrical voltage
Orari di apertura
Mounting configuration
Control requirements
Property-line restrictions
Older HID systems may already have substantial lumen depreciation, making comparisons based only on original lamp lumens misleading.
Estimate Energy Savings With Project Data
Annual lighting energy consumption can be estimated as:
Fixture wattage × fixture quantity × annual operating hours ÷ 1,000
Annual energy cost can then be estimated as:
Annual kWh × electricity rate
Retrofit economics should additionally account for installation labor, maintenance, controls, utility incentives, and total project cost.
A universal energy-saving percentage or payback period should not be applied because results depend on the existing system and operating conditions.
Different Parking Facilities Have Different Priorities
Similar parking areas can require different lighting strategies because their users and operating conditions differ.
| Parking Application | Main Lighting Priorities |
|---|---|
| Shopping centers and retail | Pedestrian visibility, uniformity, glare control |
| Hospitals and healthcare facilities | 24/7 circulation, entrances, crossings, accessible routes |
| Office and corporate campuses | Controls, low-traffic dimming, pedestrian circulation |
| Logistics and industrial sites | Vehicle movement, security zones, large-area coverage |
| Auto dealerships | Color recognition, vertical illumination, vehicle presentation |
| Hotels and hospitality properties | Visual comfort, pedestrian routes, property appearance |
Within one property, entrances, crossings, loading areas, perimeter zones, and general parking spaces may also require different criteria.
Common Parking Lot Lighting Specification Mistakes
Selecting Wattage Before Reviewing Photometrics
Wattage describes electrical input rather than installed pavement performance.
Establish the required lighting result and site geometry before selecting output.
Comparing HID and LED by Lamp Lumens Alone
LED optics and HID reflector systems distribute light differently, while existing HID lumen depreciation further limits direct lumen comparisons.
Evaluate maintained site performance instead.
Using One Distribution for Every Pole
Interior, perimeter, roadway, and corner poles serve different areas. One optic throughout the site can increase spill light or leave areas underlit.
Ignoring Backlight Near Property Boundaries
Perimeter fixtures can provide useful forward coverage while sending unnecessary light behind the pole.
Review photometric performance at the property boundary before finalizing the optic and orientation.
Looking Only at Average Illuminance
A satisfactory average can conceal low minimum points and excessively bright hotspots.
Average, minimum, maximum, and uniformity should be evaluated together.
Verify the Layout With IES Photometric Data
Fixture specifications can narrow product selection, but complete site performance depends on pole locations, mounting heights, orientation, geometry, and interaction between multiple luminaires.
An IES photometric file describes a luminaire’s luminous-intensity distribution and can be used in lighting-design software to evaluate:
Average and minimum illuminance
Uniformità
Coverage between poles
High-intensity areas
Perimeter spill light
Potential dark zones
Photometric analysis becomes particularly valuable when reducing fixture quantity, changing mounting height, replacing HID luminaires, modifying pole spacing, or working near residential boundaries.
Final layouts should be evaluated against applicable project requirements and, where appropriate, verified with field measurements after installation.
What Do We Need for Your Parking Lot Lighting Project?
Project information allows fixture selection to be based on the actual site.
| What You Provide | What STARLAKE Can Help Evaluate |
|---|---|
| Site plan and dimensions | Suitable fixture output |
| Pole locations and spacing | Optical distribution |
| Altezza di montaggio | Coverage and photometric suitability |
| Target light levels | Preliminary fixture configuration |
| Electrical voltage | Driver and voltage configuration |
| Operating schedule | Lighting control options |
| Existing fixture information | HID retrofit direction |
| Property-line conditions | Backlight and spill-light considerations |
| Requisiti di certificazione | Suitable product configurations |
For retrofits, photographs and information about existing wattage, mounting method, pole spacing, and current lighting problems can further improve the evaluation.
If the project requires engineering review, send this site information to STARLAKE for a project-specific fixture and optical evaluation.
Why Work With STARLAKE for Parking Lot Lighting?
Parking lot luminaires combine optical, electrical, thermal, mechanical, and control requirements within one outdoor platform.
Founded in 2010, STARLAKE has engineering capabilities covering optical design, power supplies, thermal management, mechanical structures, digital controls, and LED integration.
Manufacturing and engineering resources include approximately 280,000 square feet of production space, 50+ engineers, 30+ quality-control personnel, and 100+ technical patents.
For commercial parking lot lighting and area lighting programs, STARLAKE can support:
Multiple photometric distributions and mounting configurations
Wide-voltage project requirements
Photocell, dimming, and control options
Photometric data for project evaluation
OEM, ODM, white-label, and private-label programs
Packaging and labeling customization
Volume production and long-term supply programs
Quality-control and aging-test procedures
Bulk orders undergo an eight-hour aging test, while new product development includes extended high-temperature testing as part of product validation.
STARLAKE also maintains warehouse capacity in Ohio for selected North American inventory and replenishment support.
Certification should be confirmed for the specific model and configuration. Depending on the product, STARLAKE lighting programs may support certifications or qualifications including UL, ETL, DLC, and FCC.
Build the Parking Lot Around Photometric Performance
Effective illuminazione del parcheggio depends on useful illuminance, uniform coverage, controlled glare, appropriate distribution, outdoor reliability, and efficient electrical operation across the actual site.
Whether the project involves new construction, HID replacement, multi-site sourcing, or private-label area lighting, fixture configuration should follow pole geometry, photometric requirements, electrical conditions, environmental exposure, and controls.
Send STARLAKE your site plan, pole height, pole spacing, voltage, existing fixture information, and target lighting requirements for project-specific parking lot lighting evaluation.






