LED Explosion Proof Light

LED Explosion Proof Light manufacturer
SHC01 Round LED Explosion Proof Light

SHC01 Round LED Explosion Proof Light

  • Lumens: 10,000–30,000 lm (Selectable)
  • Voltage: 120–347V AC / 347–480V AC
  • CCT: 3000K / 4000K / 5000K / 5700K
  • Optics: 60° / 90° / 120°
  • Dimming: 0–10V / PWM / Rx (3-in-1)
  • Mount: Trunnion / Wall / Pendant / Round Pole / Ceiling
  • IP Rating: IP66
EPLC01 LED Explosion Proof Light

EPLC01 LED Explosion Proof Light

  • Power: 30W–200W
  • Efficacy: 130 lm/W
  • Voltage: 100–277V AC, 50–60Hz
  • CCT: 3000K–6500K
  • Beam Angle: 120°
  • Power Factor: >0.95
  • Lifetime: 50,000 Hours (L70)
EPLL01 LED Explosion Proof Light

EPLL01 LED Explosion Proof Light

  • Power: 40W–150W
  • Efficacy: 120 lm/W
  • Voltage: 100–277V AC, 50–60Hz
  • CCT: 3000K–6500K
  • Beam Angle: 90° / 110°
  • Power Factor: >0.95
  • Lifetime: 50,000 Hours (L70)
EPLL02 LED Explosion Proof Light

EPLL02 LED Explosion Proof Light

  • Power: 30W–75W
  • Luminous Flux: 120–140 lm/W
  • Voltage: 100–277V AC, 50–60Hz
  • CCT: 3000K–6500K
  • Beam Angle: 120°
  • Mount: Ceiling / Pendant / Chain / Wall / Pole
  • Lifetime: 50,000 Hours (L70)

EPLR01 LED Explosion Proof Light

  • Power: 40W / 100W / 185W
  • Lumens: 5,200 lm / 13,000 lm / 24,050 lm
  • Efficacy: 130 lm/W
  • Voltage: 100–277V AC, 50–60Hz
  • CCT: 3000K–6500K
  • Beam Angle: 15° / 60° / 90° / 108° / 120°
  • Power Factor: >0.97

Why Choose StarLake

ADVANCED MANUFACTURING

Manufacturing Excellence Behind Every Lighting Solution

At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.

CERTIFICATION & COMPLIANCE

Certified for Performance, Safety, and Market Compliance

Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.

LOCAL DELIVERY ADVANTAGE

Less Waiting. More Inventory. Better Project Support.

Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.

STARLAKE offers LED explosion proof lighting in round, high-bay, linear, and floodlight configurations for industrial buyers evaluating hazardous-location lighting requirements. Selecting a suitable luminaire requires matching its certification and operating limits to the site conditions, then assessing whether its light distribution meets the needs of the work area.

How to Choose the Right LED Explosion Proof Light

Start with the hazardous-area classification and the combustible material present. Under the North American NEC system, Class I covers flammable gases or vapors, Class II covers combustible dust, and Class III covers ignitable fibers or flyings. Division 1 and Division 2 distinguish the conditions under which these hazards may occur.

International projects may use Zone classifications under IEC-based standards and applicable regional regulations. Because classification systems and certification requirements differ, equipment selection must follow the codes and regulations governing the installation.

Next, verify the luminaire’s certification, gas or dust group, temperature classification, and permitted ambient temperature. These requirements determine whether a specific model is suitable for the identified hazard. Fixture type, mounting position, and optical distribution can then be evaluated against the lighting task.

For example, high-bay luminaires may suit elevated mounting positions, linear fixtures can be considered for elongated work areas, and floodlights may support directional illumination. Round luminaires offer another configuration to assess according to the required distribution and installation conditions. The fixture’s form alone does not establish its suitability for a hazardous location.

Compare Fixture Types and Lighting Performance

STARLAKE’s product range provides several fixture configurations for evaluation against different installation requirements. Buyers should compare the relevant specifications and photometric data rather than assume that fixtures with similar wattage will deliver equivalent lighting results.

The SHC01 round series, for example, offers 60°, 90°, and 120° distribution options. Choosing among them requires consideration of mounting height, fixture spacing, target illuminance, and the area to be illuminated.

Lumen Output and Work-Plane Illuminance

Luminous flux, measured in lumens, describes the visible light emitted by a source or luminaire. Illuminance, measured in lux or foot-candles, describes the light reaching a surface. A higher lumen rating does not necessarily mean better visibility at the working plane.

Two luminaires with similar lumen output can produce different results because of their intensity distribution, mounting height, orientation, and surrounding surfaces. A narrow distribution concentrates light over a more limited area, while a broader distribution spreads it over a wider region. The appropriate choice depends on the required illuminance and uniformity.

For pipe racks, processing equipment, and industrial access routes, review the proposed lighting layout rather than relying on lumen output alone. Photometric files and lighting calculations help assess fixture spacing, potential dark areas, and illumination across the intended work surfaces.

Glare, Thermal Management, and Efficiency

Glare depends partly on the brightness visible from a worker’s viewing position, as well as fixture orientation, mounting height, and optical distribution. Workers inspecting overhead piping or reading elevated instruments may look directly toward a luminaire, making fixture placement and viewing angles important considerations. A beam angle alone cannot establish whether a lighting arrangement will provide comfortable visibility.

Thermal management affects both LED operation and hazardous-location suitability. The luminaire must remain within its specified operating conditions, including its permitted ambient temperature and certified maximum surface temperature. These limits must be checked against the requirements of the installation rather than inferred from the LED technology alone.

Lighting efficacy, expressed in lumens per watt (lm/W), helps compare luminous output with electrical input. However, a meaningful comparison also considers required illuminance, light distribution, operating hours, and maintenance requirements.

Certifications and Hazardous-Area Requirements

Explosion proof lighting must have the approvals required for its intended hazardous location. Depending on the market and project, applicable requirements may involve UL 844, relevant CSA standards, ATEX, IECEx, or other national certification frameworks. The governing jurisdiction and project specifications determine which requirements apply.

Before purchasing, verify the exact model’s certification documents, protection concept, hazardous-area marking, gas or dust group, temperature rating, and permitted operating conditions. Do not assume that a certification held by one model applies to every product in the same series.

Temperature classification is particularly important where flammable gases or vapors are present. T4 corresponds to a maximum surface temperature of 135°C, while T6 corresponds to 85°C under the applicable rating conditions. The required classification depends on the hazardous material’s ignition characteristics and the equipment’s approved rating. These general definitions do not establish that a particular STARLAKE model carries either rating.

Ingress protection is a separate consideration. IP66 and IP67 describe resistance to dust and water ingress under specified test conditions; neither rating independently establishes suitability for an explosive atmosphere. A luminaire must meet both the applicable hazardous-location requirements and the environmental protection requirements of the installation.

If the site’s classification or certification requirements are uncertain, consult the responsible electrical engineer, hazardous-area specialist, or authority having jurisdiction before finalizing the selection.

Applications of LED Explosion Proof Lighting

The appropriate luminaire depends on the combustible material, classified location, environmental exposure, and lighting task.

Oil and gas facilities: Refineries, gas processing facilities, storage installations, and drilling operations may require lighting around process equipment, access routes, and maintenance areas. Selection must account for the classified location, temperature rating, mounting arrangement, and exposure to moisture or corrosive conditions.

Chemical and petrochemical plants: Processing and storage areas may involve flammable vapors alongside chemical exposure or demanding ambient conditions. Buyers should verify hazardous-location approval separately from enclosure protection and corrosion resistance.

Combustible-dust environments: Grain handling, flour processing, woodworking, and certain manufacturing operations may present dust-related ignition risks. Equipment approved for gas hazards should not automatically be assumed suitable for combustible dust; the required dust classification and protection must be confirmed.

Industrial work areas and access routes: Pipe racks, processing equipment, and access corridors may need different light distributions within the same facility. Fixture placement should account for obstructions, mounting positions, required illuminance, and the visibility needed for inspection or movement.

These are potential application categories, not blanket approvals for every STARLAKE luminaire. Suitability must be confirmed against the certification and technical documentation for the selected model.

Operating Costs and Maintenance Planning

The total cost of an industrial lighting installation includes more than the purchase price. Electricity consumption, maintenance labor, access equipment, replacement parts, and operational disruption can all affect lifecycle costs.

LED lighting may reduce energy consumption compared with less efficient existing technologies when the replacement system provides the required illumination. Actual savings depend on the existing fixtures, replacement wattage, operating hours, energy prices, and lighting design. Project-specific calculations are more reliable than applying a universal savings percentage.

Maintenance access is particularly relevant in hazardous locations. Reaching elevated or restricted fixtures may require specialized equipment, shutdown coordination, or additional safety procedures. A documented service-life rating can support maintenance planning, but the rated life of an LED component is not a guarantee that the complete luminaire will operate maintenance-free for the same period.

For procurement comparisons, evaluate electrical input, required light levels, rated service life, environmental suitability, warranty terms, and maintenance requirements together.

Why Choose STARLAKE for LED Explosion Proof Lighting?

Founded in 2010, STARLAKE operates in the LED lighting industry with production facilities in Shenzhen and Cambodia and U.S. warehouse locations in Ohio and California. This manufacturing and distribution footprint provides useful background for distributors, importers, contractors, and industrial procurement teams evaluating potential suppliers.

Product selection should still be based on model-specific evidence. Buyers should review the relevant certification documents, electrical specifications, photometric information, mounting requirements, and environmental ratings before determining whether a luminaire meets their project needs.

When discussing a project with STARLAKE, provide the intended application, hazardous-area classification, mounting conditions, and applicable certification requirements. These details help identify which available configurations warrant further technical review.

Request a Quote for LED Explosion Proof Lighting

Looking for LED explosion proof lighting for an industrial project or distribution program? Contact STARLAKE to review the relevant product specifications and discuss your requirements.

Share your project location, hazardous-area classification, preferred fixture type, and mounting conditions to help identify which available configurations warrant further evaluation.

Request a Quote

FAQs

What is an LED explosion proof light?

An LED explosion proof light is a luminaire designed and certified for specified hazardous locations where flammable gases, vapors, or combustible dust may be present. Its suitability depends on the applicable protection design, certification, hazardous-area marking, and operating conditions.

No. IP66 and IP67 describe protection against dust and water ingress under specified test conditions. They do not independently demonstrate compliance with hazardous-location requirements. The luminaire must have the appropriate approval for the intended explosive atmosphere.

Identify the hazardous-area classification and combustible material first. Then verify the required certification, gas or dust group, temperature rating, ambient conditions, and mounting arrangement. Use the product’s photometric information to assess illuminance and uniformity where necessary.

Provide the project location, intended application, hazardous-area classification, required power or light output, mounting conditions, and applicable certification requirements. Existing specifications or equipment markings can help clarify the selection criteria. Final suitability should be confirmed against the relevant product documentation.

Have any questions?

Feel free to contact us anytime - +86 139 0248 9327