Commercial LED Panel Lights for Professional Interior Projects

LED Panel Light factory

BPL LED Panel Light

  • Housing: Aluminum frame, white painted.
  • Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
  • Mounting: Ceiling Installation, Suspension rod.
  • Certification list: DLC 6.0 Premium/ETL.
  • Recommended Use: New construction or remodel, Office, Schools, Healthcare facilities, Institutions and commercial applications.
  • Distribution: 120°.

Specifications

Part NoPowerLuminous FluxCCTInput Voltage
SS-BPL14-40/30/25/20/15W40W / 30W / 25W / 20W / 15W5200lm3500K / 4000K / 5000K / 5700K / 6500K SelectableAC120-277V / AC120-347V
SS-BPL22-40/30/25/20/15W40W / 30W / 25W / 20W / 15W5200lm3500K / 4000K / 5000K / 5700K / 6500K SelectableAC120-277V / AC120-347V
SS-BPL24-50/40/35/30/25W50W / 40W / 35W / 30W / 25W6500lm3500K / 4000K / 5000K / 5700K / 6500K SelectableAC120-277V / AC120-347V
SS-BPL24-72W-Tx(xx)72W / 60W / 50W / 40W / 30W9360lm3500K / 4000K / 5000K / 5700K / 6500K SelectableAC120-277V / AC120-347V

Dimensions

Additional Accessory

Product Categories

Contact Us

Please enable JavaScript in your browser to complete this form.

Why Choose StarLake

ADVANCED MANUFACTURING

Manufacturing Excellence Behind Every Lighting Solution

At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.

CERTIFICATION & COMPLIANCE

Certified for Performance, Safety, and Market Compliance

Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.

LOCAL DELIVERY ADVANTAGE

Less Waiting. More Inventory. Better Project Support.

Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.

STARLAKE commercial LED panel lights provide broad, uniform illumination for offices, schools, healthcare facilities, retail spaces and other commercial interiors where visual comfort, clean ceiling integration and flexible lighting control matter.

Our slim LED flat panel lights combine selectable wattage, 3500K/4000K/5000K selectable CCT, 120° light distribution and 0-10V dimming. Recessed and flush-mount configurations support different commercial ceiling conditions, while optional occupancy controls provide additional flexibility for project applications.

For lighting brands, distributors and contractors, STARLAKE also supports OEM and ODM programs backed by in-house engineering, manufacturing, quality control and North American warehouse support.

Send us your ceiling type, fixture quantity, voltage, controls and target application. We can help review the appropriate configuration for your project.

Uniform Commercial Lighting Starts With Light Distribution

The advantage of an LED panel is not simply its slim appearance. Its broad luminous surface helps transform the concentrated output of individual LEDs into more evenly distributed ambient illumination.

This matters because total lumens alone do not determine lighting quality. A fixture can produce sufficient lumens but still create poor task-plane results if its distribution and spacing do not match the room.

For offices, classrooms and other spaces occupied for long periods, specification should consider:

  • Target illuminance

  • Fixture lumen output

  • Mounting height

  • Fixture spacing

  • Light distribution and uniformity

  • Direct-view brightness and glare

  • Ceiling geometry and reflectance

STARLAKE’s current panel platform uses a 120° lighting angle for broad general illumination.

The basic design relationship is:

Distribution → Mounting Height → Spacing → Illuminance → Uniformity

Increasing spacing may reduce fixture quantity, but excessive spacing can create lower-illuminance areas between luminaires. Adding more output does not necessarily correct a poor layout.

For larger projects, final spacing and fixture quantity should be verified using fixture-specific photometric data or an IES-based lighting layout.

Selectable Wattage for Different Project Requirements

Commercial projects rarely require the same output in every room.

STARLAKE’s current slim panel platform provides selectable wattage, allowing one fixture family to cover several output requirements.

Fixture FormatSelectable WattageLumen Output
2FT10W / 15W / 20W1,000 / 1,500 / 2,000 lm
4FT25W / 30W / 40W2,500 / 3,000 / 4,000 lm

Rated efficacy is 100 lm/W.

For contractors, selectable wattage provides flexibility when room sizes and target light levels vary within the same project. For distributors, it can reduce the number of fixed-output SKUs required to cover common commercial applications.

Higher wattage should not automatically be treated as better.

A more reliable selection sequence is:

Application → Target Illuminance → Mounting Height → Spacing → Required Lumens → Wattage Setting

If the lower setting already delivers the required maintained light level, additional wattage may increase connected load and ceiling brightness without improving the project result.

Choose 3500K, 4000K or 5000K

STARLAKE’s selectable-CCT platform allows the same fixture to be configured at 3500K, 4000K or 5000K.

CCTVisual CharacterTypical Commercial Direction
3500KSofter neutral whiteOffices and comfort-oriented interiors
4000KBalanced neutral whiteOffices, schools and general commercial spaces
5000KCooler whiteProjects preferring a daylight-like appearance

The correct CCT depends on the intended atmosphere, visual task, interior finishes and project specification.

Selectable CCT also has an inventory advantage. Distributors can cover several common color-temperature requirements without stocking a dedicated fixture for every combination.

Within the same continuous visual zone, keep the selected CCT consistent. Mixing settings across an open office or corridor can create an obviously inconsistent ceiling.

Slim Recessed and Flush-Mount Installation

LED panel lights integrate particularly well with commercial ceiling lighting because their slim construction minimizes the visual and physical bulk associated with traditional recessed fixtures.

STARLAKE’s current platform supports recessed installation and compatible flush-mount configurations using the appropriate mounting accessories.

FormatApproximate Fixture Dimensions
2FT23.7 × 5.75 in.
4FT47.72 × 5.75 in.

The low-profile design can be useful where the ceiling cavity must also accommodate HVAC ducts, wiring, fire-protection systems and other building services.

Contractors should still verify:

  • Ceiling construction

  • Opening dimensions

  • Available plenum space

  • Mounting accessories

  • Driver location

  • Wiring access

  • Service access

For retrofit work, do not assume fixtures with similar nominal dimensions are mechanically interchangeable.

0-10V Dimming and Occupancy Controls

Commercial lighting increasingly operates according to occupancy and actual lighting demand rather than remaining at full output throughout operating hours.

STARLAKE’s current panel platform supports 0-10V dimming and sensor configurations including PIR and microwave occupancy sensing. Selected configurations also provide Bluetooth-related control functions.

These controls can support different operating strategies:

  • Dimming in offices and meeting rooms

  • Occupancy-based switching in intermittently used rooms

  • Different control strategies across a multi-room project

  • Reduced unnecessary lighting runtime

Controls should be specified before ordering.

The driver → sensor → control architecture → project wiring must be compatible. Providing the control requirement during quotation allows the electrical configuration to be reviewed before production.

Commercial Electrical Configurations

Current STARLAKE panel configurations are available for AC120-277V and AC120-347V, depending on the selected model.

Power factor is specified above 0.9 and driver efficiency above 90%.

Voltage is especially important for projects involving multiple facilities or different regional electrical systems. A mechanically suitable fixture with an incorrect driver configuration can still create significant installation problems.

Before ordering, confirm:

Voltage → Wattage → CCT → Dimming → Sensor → Mounting

Commercial LED Panel Light Applications

Offices

LED panel lights work well as general ambient lighting in open offices, private offices, conference rooms and administrative spaces.

Broad distribution supports illumination across work areas, while selectable output and CCT allow the same fixture platform to adapt to different room requirements. 0-10V dimming can provide additional flexibility where operating light levels change.

Schools

Classrooms need useful illumination across desks, teaching areas and circulation zones rather than concentrated brightness directly beneath individual fixtures.

Fixture spacing should account for desk orientation, screens, whiteboards, daylight and room geometry. Occupancy sensing can also reduce unnecessary runtime in classrooms and support spaces with intermittent use.

Healthcare Facilities

Panel lights can provide general ambient lighting in appropriate administrative areas, offices, corridors and other compatible healthcare interiors.

The current STARLAKE BPL specification is IP20. Specialized clinical, wet, cleanroom or sanitation-sensitive spaces may require different ingress protection, construction or regulatory characteristics and should be evaluated separately.

Retail and General Commercial Interiors

Panel lights can provide the general ambient layer for retail floors, checkout areas, circulation spaces and back-of-house environments.

Where merchandise needs visual emphasis, combine general panel lighting with directional track or accent lighting rather than attempting to make one fixture perform both functions.

Replacing Fluorescent Commercial Ceiling Lighting

LED flat panel lights are commonly considered when older fluorescent ceiling systems reach the end of their practical service life.

However, a retrofit should not use:

Existing Fluorescent Wattage = Required LED Wattage

That shortcut ignores ballast consumption, lamp depreciation, reflector condition, optical distribution and the actual maintained illuminance of the existing system.

Use this sequence instead:

Existing Fixture → Existing Layout → Current Light Level → Required Light Level → LED Distribution → Required Output → Controls → Installation Compatibility

Before selecting replacements, document the existing fixture quantity, ceiling layout, mounting dimensions, voltage, controls and required task-plane light level.

The objective is not simply to install fewer watts. It is to maintain or improve the required lighting result while reducing connected load and future maintenance exposure.

Commercial Panel Light Selection Guide

A structured specification process reduces both lighting-performance and purchasing risk.

Selection InputWhat to ConfirmWhy It Matters
ApplicationOffice, school, healthcare, retailEstablishes lighting priorities
Light LevelTarget lux or foot-candlesDetermines required output
CeilingHeight, type and geometryAffects mounting and spacing
OutputRequired lumensPrevents over- or underlighting
DistributionFixture photometricsAffects coverage and uniformity
CCT / CRIProject specificationDetermines visual appearance and color rendering
Voltage120-277V or 120-347V as applicableDetermines driver configuration
Controls0-10V, sensor requirementsDetermines wiring and operation
MountingRecessed or flush mountDetermines installation hardware
CertificationProject-specific requirementsReduces compliance risk
PhotometricsIES file and layoutVerifies final lighting performance

For larger projects, the last step matters. A lumen calculation can provide a preliminary estimate, but fixture-specific photometric simulation provides a much better basis for final layout decisions.

Fewer Configurations Can Mean Simpler Distributor Inventory

Project buyers and lighting distributors solve different problems.

A project buyer needs the correct configuration for one building. A distributor must stock enough configurations to serve many contractors without creating excessive inventory complexity.

Selectable wattage and CCT can help reduce that complexity.

Selectable Platform → Fewer Fixed SKUs → More Flexible Inventory → Easier Project Matching

A single configurable fixture family can cover several common combinations of output and color temperature that would otherwise require separate SKUs.

This can support:

  • SKU rationalization

  • Flexible local inventory

  • Easier contractor selection

  • Fewer specification substitutions

  • Better response to mixed project requirements

STARLAKE also maintains an Ohio/California warehouse to support North American customers requiring local inventory and more flexible replenishment.

OEM and ODM LED Panel Light Programs

Lighting brands, importers and regional distributors may require configurations beyond a standard catalog fixture.

STARLAKE supports OEM and ODM programs covering:

  • Wattage and lumen configuration

  • CCT configuration

  • Driver selection

  • Control integration

  • Optical development

  • Mechanical customization

  • Housing and appearance adjustments

  • Private labeling

  • Packaging customization

  • Certification support

  • Sample development

  • Production and quality control

Not every customization has the same engineering impact.

Label or Packaging Change → Limited Engineering Impact

Driver or Control Change → Electrical Review

Optical or Structural Change → Engineering Validation

Major Product Redesign → Potential Tooling and Certification Impact

Changes to the electrical, optical or mechanical system can affect testing, certification, MOQ and lead time. These implications should be reviewed before samples or mass production rather than discovered after the product has entered the approval process.

Why Commercial Buyers Work With STARLAKE

Selecting a commercial lighting manufacturer involves more than comparing fixture prices.

The supplier must be able to maintain electrical, optical and mechanical consistency across production while supporting engineering changes, certification requirements and long-term supply.

Engineering Support Reduces Specification Risk

STARLAKE has 50+ engineers covering areas including power supplies, thermal management, optics, mechanical design, digital controls and LED integration.

This allows electrical, optical and mechanical requirements to be reviewed as part of the same product-development process.

Manufacturing Capacity Supports Long-Term Programs

Founded in 2010, STARLAKE operates approximately 280,000 sq.ft of production space, employs more than 400 people and maintains manufacturing facilities in Shenzhen and Cambodia.

This infrastructure supports regular commercial orders as well as longer-term distributor and private-label programs.

Quality Control Helps Reduce Early Field Failures

STARLAKE has 30+ QC professionals.

Bulk production undergoes an 8-hour aging test before shipment to help identify early electrical or assembly failures. New products undergo a validation process that includes 30 days of continuous 24/7 high-temperature testing.

An aging test does not replace long-term lumen-maintenance, driver-life or thermal validation. It is one part of a broader reliability-control process.

50,000+ Hour Rating and 5-Year Limited Warranty

Current BPL configurations specify a service life of more than 50,000 hours and a 5-year limited warranty.

For distributors and lighting brands, service-life expectations and warranty coverage are important not only for end users but also for evaluating future replacement and warranty exposure.

North American Inventory Support

STARLAKE’s Ohio/California warehouse connects overseas manufacturing capacity with local North American inventory support.

For distributors and project buyers, this can improve replenishment flexibility and reduce dependence on international shipment cycles for every requirement.

What to Send for an LED Panel Light Quote

A complete RFQ allows the manufacturer to review the project faster and reduces back-and-forth during specification.

Send STARLAKE:

  • Application or facility type

  • Fixture quantity

  • Required fixture format

  • Ceiling type and mounting method

  • Target lumen output or illuminance

  • CCT and CRI requirement

  • Input voltage

  • Dimming requirement

  • Sensor or control requirement

  • Required certifications

  • OEM or private-label requirements

  • Packaging requirements

  • Delivery destination

  • Project schedule

If wattage or fixture quantity has not yet been determined, provide the room dimensions, ceiling height, target light level and available layout information instead.

Specify the Right Panel Light Before You Order

A commercial LED panel light should not be selected by wattage or price alone.

Application → Light Level → Distribution → Spacing → Electrical Configuration → Controls → Installation → Compliance

Following that sequence helps reduce overlighting, installation problems, incompatible controls and unnecessary SKU complexity.

STARLAKE combines commercial lighting engineering, scalable manufacturing, OEM and ODM development, systematic quality control and North American warehouse support for lighting brands, distributors, contractors, importers and project buyers.

Send us your fixture quantity, ceiling type, voltage, CCT, control requirements and target application. STARLAKE can review the configuration and provide product, photometric and OEM recommendations for quotation.

Commercial LED Panel Light FAQ

Have any questions?

Feel free to contact us anytime - +86 139 0248 9327