Commercial LED Panel Lights for Professional Interior Projects


BPL LED Panel Light
- Housing: Aluminum frame, white painted.
- Electrical: AC 120-277V / 120-347V input voltage; 0-10V dimming.
- Mounting: Ceiling Installation, Suspension rod.
- Certification list: DLC 6.0 Premium/ETL.
- Recommended Use: New construction or remodel, Office, Schools, Healthcare facilities, Institutions and commercial applications.
- Distribution: 120°.
Specifications
| Part No | Power | Luminous Flux | CCT | Input Voltage |
|---|---|---|---|---|
| SS-BPL14-40/30/25/20/15W | 40W / 30W / 25W / 20W / 15W | 5200lm | 3500K / 4000K / 5000K / 5700K / 6500K Selectable | AC120-277V / AC120-347V |
| SS-BPL22-40/30/25/20/15W | 40W / 30W / 25W / 20W / 15W | 5200lm | 3500K / 4000K / 5000K / 5700K / 6500K Selectable | AC120-277V / AC120-347V |
| SS-BPL24-50/40/35/30/25W | 50W / 40W / 35W / 30W / 25W | 6500lm | 3500K / 4000K / 5000K / 5700K / 6500K Selectable | AC120-277V / AC120-347V |
| SS-BPL24-72W-Tx(xx) | 72W / 60W / 50W / 40W / 30W | 9360lm | 3500K / 4000K / 5000K / 5700K / 6500K Selectable | AC120-277V / AC120-347V |
Dimensions

Additional Accessory


Product Categories
Contact Us
Why Choose StarLake
ADVANCED MANUFACTURING
Manufacturing Excellence Behind Every Lighting Solution
At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.











CERTIFICATION & COMPLIANCE
Certified for Performance, Safety, and Market Compliance
Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.









LOCAL DELIVERY ADVANTAGE
Less Waiting. More Inventory. Better Project Support.
Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.





STARLAKE commercial LED panel lights provide broad, uniform illumination for offices, schools, healthcare facilities, retail spaces, and other commercial interiors where visual comfort, clean ceiling integration, and flexible lighting control matter.
The current slim panel platform combines selectable wattage, 3500K/4000K/5000K selectable CCT, 120° light distribution, and 0–10V dimming. Recessed and compatible flush-mount configurations support different commercial ceiling conditions.
For lighting brands, distributors, contractors, importers, and project buyers, STARLAKE also provides OEM/ODM engineering, manufacturing, quality control, and North American supply support.
Uniform Commercial Lighting Starts With Light Distribution
An LED panel’s broad luminous surface helps distribute LED output across a larger emitting area for general ambient illumination.
The lighting result depends on more than total lumens.
For offices, classrooms, and other occupied interiors, evaluate:
Target illuminance
Fixture output
Mounting height
Fixture spacing
Distribution and uniformity
Direct-view brightness and glare
Ceiling geometry and reflectance
STARLAKE’s current panel platform uses a 120° distribution.
The basic relationship is:
Distribution → Mounting Height → Spacing → Task-Plane Illuminance → Uniformity
Increasing spacing can reduce fixture quantity, but excessive spacing can create lower-illuminance zones between luminaires.
Increasing fixture output does not automatically correct an unsuitable layout.
For larger projects, verify fixture quantity and spacing using fixture-specific photometric data or an IES-based lighting layout.
Selectable Wattage for Different Project Requirements
Commercial projects can contain rooms with different dimensions, functions, and target light levels.
STARLAKE’s current slim panel platform provides selectable wattage:
| Fixture Format | Selectable Wattage | Lumen Output |
|---|---|---|
| 2FT | 10W / 15W / 20W | 1,000 / 1,500 / 2,000 lm |
| 4FT | 25W / 30W / 40W | 2,500 / 3,000 / 4,000 lm |
Rated efficacy is 100 lm/W.
Selection should follow:
Application → Target Illuminance → Room Geometry → Spacing → Required Output → Wattage Setting
For contractors, selectable output provides flexibility across rooms with different lighting requirements.
For distributors:
One Panel Platform → Multiple Output Settings → Fewer Fixed SKUs
The highest wattage setting should not be used automatically. If a lower setting already achieves the required maintained illuminance, additional output increases connected load without necessarily improving the lighting result.
Choose 3500K, 4000K or 5000K
STARLAKE’s selectable-CCT platform provides 3500K, 4000K, and 5000K settings.
| CCT | Visual Character | Typical Commercial Direction |
|---|---|---|
| 3500K | Softer neutral white | Comfort-oriented commercial interiors |
| 4000K | Balanced neutral white | General offices, schools, and commercial spaces |
| 5000K | Cooler white | Projects specifying a cooler visual appearance |
CCT should follow the intended atmosphere, visual task, interior finishes, and project specification rather than a universal application rule.
Selectable CCT also reduces the number of fixed configurations distributors may need to stock.
Within one continuous visual zone, keep the commissioned CCT consistent unless the lighting design intentionally specifies otherwise. Unplanned mixing can create visible differences across the ceiling.
Slim Recessed and Flush-Mount Installation
Commercial panel lighting must fit both the lighting layout and the ceiling system.
STARLAKE’s current platform supports recessed installation and compatible flush-mount configurations using the appropriate mounting accessories.
| Format | Approximate Fixture Dimensions |
|---|---|
| 2FT | 23.7 × 5.75 in. |
| 4FT | 47.72 × 5.75 in. |
The slim profile can be useful where the ceiling cavity also contains HVAC ducts, wiring, fire-protection systems, and other building services.
Before ordering, verify:
Ceiling construction
Opening dimensions
Available plenum space
Mounting accessories
Driver location
Wiring access
Service access
A useful installation chain is:
Ceiling Type → Available Space → Fixture Dimensions → Mounting Method → Driver / Wiring Access → Serviceability
For retrofit projects, do not assume that fixtures with similar nominal dimensions are mechanically interchangeable.
0–10V Dimming and Occupancy Controls
STARLAKE’s current panel platform supports 0–10V dimming and sensor configurations including PIR and microwave occupancy sensing. Selected configurations also provide Bluetooth-related control functions.
Depending on the project, controls can support:
Dimming in offices and meeting rooms
Occupancy-based operation in intermittently used spaces
Different operating strategies across multiple rooms
Reduced unnecessary full-output runtime
Controls should be specified before ordering.
Compatibility depends on the complete system:
Driver → Sensor → Control Architecture → Project Wiring
A fixture that supports 0–10V dimming does not automatically establish compatibility with every sensor, control system, or wiring arrangement.
Providing control requirements during quotation allows the electrical configuration to be reviewed before production.
Commercial Electrical Configurations
Current STARLAKE panel configurations are available for AC120–277V and AC120–347V, depending on model.
Power factor is specified above 0.9, with driver efficiency above 90%.
Electrical configuration becomes especially important for multi-building projects or distribution programs serving different regional systems.
Before ordering, confirm:
Voltage → Wattage → CCT → Dimming → Sensor → Mounting
Mechanical fit alone does not establish electrical compatibility.
Commercial LED Panel Light Applications
LED panels primarily serve as a broad ambient-lighting layer in compatible commercial interiors.
| Application | Panel Light Role | Key Variables |
|---|---|---|
| Offices | General ambient lighting | Task-plane illuminance, spacing, glare, controls |
| Schools | Classroom and support-space ambient lighting | Desk illumination, spacing, controls |
| Healthcare Interiors | General lighting in compatible non-specialized areas | Visual comfort, application requirements |
| Retail | General ambient layer | Uniformity, ceiling integration, coordination with accent lighting |
Offices
Panel lights can provide general ambient illumination across open offices, private offices, conference rooms, and administrative spaces.
Final layouts should account for work-plane requirements, fixture spacing, ceiling conditions, daylight, and controls.
Schools
In classrooms, panel lighting should provide useful illumination across desks and circulation areas rather than concentrating brightness directly beneath individual fixtures.
Detailed classroom design should also consider teaching surfaces, screens, daylight, and room geometry.
Healthcare Facilities
Panel lights can provide general ambient illumination in appropriate administrative areas, offices, corridors, and other compatible healthcare interiors.
The current STARLAKE BPL specification is IP20.
Specialized clinical, wet, cleanroom, sanitation-sensitive, or other regulated environments may require different construction, ingress protection, or compliance characteristics.
Retail and General Commercial Interiors
Panel lights can provide the ambient layer for retail floors, checkout areas, circulation spaces, and back-of-house areas.
Where merchandise requires visual emphasis:
Panel Lighting → General Ambient Layer
Track / Accent Lighting → Directional Emphasis
One fixture type does not need to perform both roles.
Replacing Fluorescent Commercial Ceiling Lighting
LED flat panels are frequently considered when older fluorescent ceiling systems require modernization.
Do not use:
Existing Fluorescent Wattage = Required LED Wattage
That shortcut ignores ballast consumption, lamp depreciation, reflector condition, optical distribution, and existing maintained illuminance.
Use:
Existing Fixture → Existing Ceiling Layout → Current Light Level → Required Light Level → LED Distribution → Required Output → Controls → Installation Compatibility
Before specifying replacements, document:
Existing fixture quantity
Ceiling layout
Fixture dimensions
Mounting method
Voltage
Controls
Required task-plane illuminance
The replacement should maintain or improve the required lighting result rather than simply reduce fixture wattage.
Mechanical compatibility should also be verified because an LED panel retrofit may interact differently with the existing ceiling, mounting hardware, driver location, and wiring.
Commercial Panel Light Selection Guide
A structured specification process reduces lighting, installation, and purchasing risk.
| Selection Input | What to Confirm | Why It Matters |
|---|---|---|
| Application | Intended room or space | Establishes lighting priorities |
| Light Level | Target lux or foot-candles | Determines required output |
| Ceiling | Height, type, geometry | Affects mounting and spacing |
| Output | Required lumens | Helps prevent over- or underlighting |
| Distribution | Fixture photometrics | Affects coverage and uniformity |
| CCT / CRI | Project specification | Determines appearance and color rendering |
| Voltage | 120–277V or 120–347V | Determines driver configuration |
| Controls | 0–10V, sensor requirements | Determines electrical architecture |
| Mounting | Recessed or flush mount | Determines installation hardware |
| Certification | Project-specific requirements | Determines compliance suitability |
| Photometrics | IES file and layout | Verifies final lighting performance |
The overall selection chain is:
Application → Task Plane → Ceiling → Distribution → Spacing → Output → Electrical Configuration → Controls → Installation
For larger projects, lumen calculations can provide preliminary estimates, but fixture-specific photometric simulation provides a stronger basis for final quantity and layout.
Selectable Configurations for Distributor Inventory
Project buyers and distributors have different configuration requirements.
A project buyer needs the correct panel for a defined building. A distributor may need to cover several output and CCT requirements without carrying every possible fixed combination.
Selectable wattage and CCT create the relationship:
One Configurable Platform → Multiple Project Settings → Fewer Fixed SKUs → Lower Inventory Complexity
This can support mixed project requirements while reducing unnecessary product variants.
STARLAKE also maintains warehouse support in Ohio and California for selected North American inventory and replenishment requirements.
OEM and ODM LED Panel Light Programs
STARLAKE supports OEM and ODM programs for lighting brands, importers, distributors, contractors, and project suppliers.
Customization can involve:
Wattage and lumen configuration
CCT configuration
Driver selection
Control integration
Optical development
Mechanical customization
Housing and appearance
Private labeling
Packaging
Certification support
Not every modification has the same engineering impact:
Label / Packaging Change → Limited Engineering Impact
Driver / Control Change → Electrical Review
Optical Change → Photometric Validation
Structural Change → Mechanical / Installation Review
Major Redesign → Potential Tooling + Validation + Certification Impact
Changes affecting the electrical, optical, or mechanical system should be evaluated before sample approval and mass production.
STARLAKE has 50+ engineers supporting areas including power supplies, thermal management, optics, mechanical design, controls, and LED integration.
Manufacturing & Quality Control
STARLAKE has manufactured LED lighting since 2010 and operates approximately 280,000 sq.ft of production space with manufacturing operations in Shenzhen and Cambodia.
The company employs more than 400 people, including 30+ QC professionals supporting manufacturing quality control.
Bulk production undergoes an 8-hour aging test before shipment. New products undergo validation that includes 30 days of continuous high-temperature testing.
These processes support early electrical, component, thermal, and assembly screening. They do not replace long-term lumen-maintenance data, driver-life evaluation, or application-specific certification.
Current BPL configurations specify more than 50,000 hours of service life and a 5-year limited warranty.
Product-specific warranty, certification, and configuration requirements should be confirmed for the selected model and market.
What to Send for an LED Panel Light Quote
For project evaluation or quotation, provide:
Application or facility type
Fixture quantity
Required fixture format
Ceiling type and mounting method
Target lumen output or illuminance
CCT and CRI requirement
Input voltage
Dimming requirement
Sensor or control requirement
Required certifications
OEM or private-label requirements
Packaging requirements
Delivery destination
Project schedule
If wattage or fixture quantity has not yet been determined, provide room dimensions, ceiling height, target light level, and available layout information instead.
STARLAKE can then evaluate:
Panel Format → Distribution → Output → Spacing → Electrical Configuration → Controls → Mounting
around the actual project requirements rather than recommending a panel light from wattage alone.
Specify the Right Panel Light Before You Order
Commercial LED panel selection should begin with the required lighting result and ceiling conditions.
A practical sequence is:
Application → Task-Plane Illuminance → Distribution → Spacing → Output → Ceiling Compatibility → Electrical Configuration → Controls
STARLAKE supports standard and customized panel-light programs for commercial projects, distributors, contractors, importers, and lighting brands.


