LED Stadium Lights

LED Area Light factory

SR04 LED Stadium Lights

  • Power: 300W–1200W (Selectable Options)
  • Efficacy: Up to 150 lm/W
  • Voltage: AC120–277V / AC120–347V / AC277–480V
  • CCT: 4000K / 5000K / 5700K
  • Beam Angle: 20° / 40° / 50° / 60° (Model Dependent)
  • Rating: Wet Location
  • Lifetime: Over 50,000 Hours

SR05 LED Stadium Lights

  • Power: 300W–1200W (Selectable Options)

  • Efficacy: Up to 150 lm/W

  • Voltage: AC120–277V / AC120–347V / AC200–480V

  • CCT: 4000K / 5000K / 5700K / 6500K (Optional)

  • Beam Angle: 15° / 25° / 40° / 60°

  • Rating: Wet Location

  • Lifetime: Over 50,000 Hours

Why Choose StarLake

ADVANCED MANUFACTURING

Manufacturing Excellence Behind Every Lighting Solution

At STARLAKE, every commercial lighting product is backed by standardized manufacturing, rigorous quality control, and continuous process improvement. From engineering and component assembly to testing and packaging, our production system is designed to deliver consistent quality, reliable performance, and dependable delivery for every order.

CERTIFICATION & COMPLIANCE

Certified for Performance, Safety, and Market Compliance

Every STARLAKE lighting product is developed and manufactured to meet the certification and compliance requirements of major commercial markets. Our products are tested and certified by internationally recognized organizations, helping distributors, contractors, and lighting brands simplify project approval and ensure long-term reliability.

LOCAL DELIVERY ADVANTAGE

Less Waiting. More Inventory. Better Project Support.

Local warehousing enables faster shipping, simplified logistics, and better inventory planning. From routine orders to time-sensitive commercial projects, STARLAKE provides dependable fulfillment that helps customers reduce downtime and meet project deadlines.

STARLAKE manufactures 300W to 1200W LED stadium lights for sports fields, stadiums, and outdoor athletic facilities. Our stadium floodlights deliver up to 150 lm/W, with beam angles from 15° to 60° and multiple voltage configurations for different pole arrangements and field layouts.

We provide OEM and ODM customization, product engineering, and manufacturing support for lighting distributors, contractors, and commercial project buyers.

LED Stadium Lighting Applications

Different sports require different combinations of horizontal illuminance, vertical illuminance, uniformity, and glare control. Field geometry and pole placement also affect the optical distribution needed.

Application

Main Lighting Challenge

Selection Priority

Soccer and Football Fields

Maintaining visibility across large playing areas

Horizontal and vertical illuminance, uniformity, pole placement

Baseball and Softball Fields

Tracking airborne balls from different viewing positions

Long-distance projection, aiming angles, glare control

Running Tracks and Athletics Facilities

Covering the track and interior activity zones

Beam overlap, illuminance uniformity

Community and School Sports Fields

Meeting lighting needs within installation and operating budgets

Fixture quantity, mounting height, target illuminance

Multi-Purpose Stadiums

Accommodating different sports and operating schedules

Lighting zones, control compatibility, adjustable output

For televised competitions, additional requirements may apply to camera-oriented vertical illuminance, color rendering, and temporal light quality. These must be evaluated against the applicable competition and broadcasting specifications.

Precision Optics for Stadium Lighting

Luminous intensity distribution (LID) determines how a stadium floodlight directs its output toward the playing field. Two fixtures with the same lumen rating can produce different illuminance patterns because of their beam distributions, mounting positions, and aiming angles.

Beam Angle and Long-Distance Projection

Narrow beams concentrate luminous intensity toward smaller target areas, making them useful for certain long-distance lighting positions. Wider beams distribute light across larger areas and can help neighboring fixtures overlap their coverage.

However, a narrower beam doesn’t automatically improve uniformity or reduce glare. Excessive concentration can create bright areas surrounded by insufficiently illuminated sections, while overly wide distributions may increase spill light beyond the field.

STARLAKE provides different optical options across its two stadium lighting series.

  • SR04 LED Stadium Lights — 20°, 40°, 50°, and 60° for 300W–600W models. The 800W–1200W models offer 20°, 40°, and 60°.

  • SR05 LED Stadium Lights — 15°, 25°, 40°, and 60°, depending on the selected model.

The SR05’s 15° option provides a narrower distribution for applications requiring concentrated projection. The final beam selection should be based on the target area, mounting geometry, and photometric calculations.

Glare and Spill Light Control

Players looking upward to track a ball may encounter direct glare when floodlights fall within their viewing direction. Light extending beyond the field can also affect nearby properties.

Both SR04 and SR05 feature visors and laser aiming devices. The visors help shield unwanted light, while the aiming devices assist installers in aligning fixtures with their intended target areas.

These components support optical control but cannot independently guarantee a particular glare rating. Final performance depends on pole positions, aiming angles, observer locations, and the surrounding environment.

IES-based software can calculate field illuminance, uniformity, and light distribution beyond the playing area. Glare assessment additionally requires an appropriate evaluation method and defined observer positions.

How to Choose LED Stadium Lights

Stadium lighting selection should begin with the required field performance, followed by mounting geometry, optical distribution, and electrical compatibility.

Establish Illuminance and Uniformity Targets

Horizontal illuminance measures light incident on the playing surface. Vertical illuminance describes light incident on vertical planes and becomes especially important when cameras must capture players and moving objects from specific directions.

Uniformity describes how consistently illuminance is distributed across the evaluated area. A high average illuminance cannot compensate for excessively dark sections of the field.

Required illuminance and uniformity values depend on the sport, competition level, and applicable lighting criteria.

For professional broadcasting, confirm the required camera directions, frame rates, color rendering, and flicker-performance criteria before finalizing the luminaire and driver configuration. Standard SR04/SR05 specifications alone do not establish broadcast compliance.

Match Beam Angles to Pole Positions

Pole height is only one variable in beam selection. The horizontal distance to the target area, fixture orientation, and overlap with neighboring luminaires also affect the resulting illuminance.

A distant section of a football field may require a narrower distribution than an area closer to the pole. Larger fields may benefit from combining multiple beam angles within the same installation.

Photometric simulations using the selected fixtures’ IES files can compare illuminance, uniformity, and spill light before installation.

Verify Electrical and Structural Compatibility

STARLAKE offers several voltage configurations across its stadium lighting series.

Series

Available Input Voltage Options

SR04

AC120–277V / AC120–347V / AC277–480V

SR05

AC120–277V / AC120–347V / AC200–480V

Confirm the selected model’s voltage range, driver, mounting bracket, weight, and dimming compatibility before ordering.

High-mast installations also require structural verification of poles, mounting hardware, and wind loads. A compatible electrical connection does not establish that an existing pole can safely support a replacement luminaire.

Information Needed for a Stadium Lighting Quote

A project inquiry should include the following details.

  • Field dimensions and sport — Playing area and intended use.

  • Pole arrangement — Number, positions, and mounting heights.

  • Lighting targets — Required illuminance, uniformity, and competition level.

  • Electrical requirements — Supply voltage and control requirements.

  • Project type — New installation or replacement of existing fixtures.

  • Procurement details — Estimated quantities, destination market, and project schedule.

These details help identify suitable fixture configurations and determine whether additional lighting calculations or installation information are required.

Outdoor Protection and Reliability

Elevated stadium lighting installations can require specialized equipment for maintenance. Fixture reliability therefore affects both component replacement costs and access expenses.

Thermal Management

LED operating temperature influences lumen maintenance and the reliability of electronic components.

Both SR04 and SR05 use dedicated heat-dissipation structures. The SR04 also incorporates a ventilated metal-mesh design that promotes airflow around the housing.

Actual thermal performance depends on ambient temperature, operating power, and installation conditions.

Weather and Electrical Protection

Both series are documented with IP65 enclosure designs and wet-location suitability. IP65 provides dust-tight protection and resistance to water jets under defined test conditions, but does not indicate suitability for submersion.

Both series also specify 10kV surge protection. Appropriate grounding and additional system-level surge protection may still be required depending on the installation.

The product specifications state a rated lifetime exceeding 50,000 hours and a five-year limited warranty. These values do not guarantee maintenance-free operation and should be interpreted according to the applicable product and warranty documentation.

LED Stadium Lights vs. Metal Halide Lighting

LED stadium lighting retrofits can reduce energy consumption and eliminate routine HID lamp replacement. However, replacement fixtures must deliver the required illuminance and uniformity using the existing or proposed pole arrangement.

Comparison

Metal Halide Lighting

LED Stadium Lighting

Startup

Requires warm-up

Immediate light output

Restart

May require cooling before restrike

Generally supports immediate restart

Dimming

Limited or requires specialized equipment

Available with compatible drivers

Light Distribution

Lamp and reflector dependent

Dedicated LED optical distributions

Maintenance

Periodic lamp replacement

No routine HID lamp replacement

Power Consumption

Lamp and ballast input power

LED system input power

Retrofit Assessment

Existing fixture and pole arrangement

Photometric and structural verification

Estimate Energy Savings

Compare actual system input power rather than lamp wattage alone.

Annual Energy Savings (kWh) = (Existing System Power in kW − New LED System Power in kW) × Annual Operating Hours

For example, replacing a 1.6 kW existing system load with a 1.0 kW LED load saves 0.6 kWh per operating hour. At 2,000 annual operating hours, this equals 1,200 kWh per replaced fixture position.

This is an illustrative calculation, not a measured STARLAKE project result. Actual savings depend on fixture quantity, input power, operating hours, and dimming schedules.

Retrofit costs should also include installation labor, lift rental, mounting modifications, and future maintenance access.

LED Stadium Lights Manufacturer and OEM/ODM Support

STARLAKE provides stadium lighting manufacturing and customization for distributors, importers, lighting brands, and project contractors. Our engineering capabilities include optical design, LED drivers, thermal management, mechanical structures, and lighting control integration.

OEM and ODM Customization

Available customization may include optical configurations, driver and voltage options, mechanical components, branding, labeling, and packaging, subject to technical feasibility.

Changes to electrical or optical components may require additional testing, certification review, or engineering validation. Buyers should confirm sample approval, inspection criteria, minimum order quantities, and production schedules before mass production.

Manufacturing and Quality Control

STARLAKE operates manufacturing facilities in Shenzhen and Cambodia, supported by more than 50 engineers and 30 quality-control professionals.

Bulk production orders undergo eight-hour aging tests to help identify early electrical or assembly defects. Product development also includes extended high-temperature reliability testing.

These procedures support manufacturing consistency but do not replace model-specific certification or application testing.

North American Supply Support

STARLAKE maintains a warehouse in Ohio to support its North American business. Customers can discuss sourcing arrangements involving overseas manufacturing and regional inventory support.

Specific model availability, delivery schedules, and wholesale order requirements should be confirmed during quotation.

Request an LED Stadium Lighting Quote

For new installations, metal halide retrofits, or wholesale sourcing, send STARLAKE your field dimensions, pole arrangement, lighting targets, electrical requirements, and estimated fixture quantity.

Our team can review available SR04/SR05 configurations and discuss product specifications, customization, and procurement requirements.

Contact STARLAKE to request LED stadium lighting specifications and a project quotation.

FAQ

What wattage LED stadium lights do I need for a sports field?

STARLAKE offers stadium lights from 300W to 1200W. The appropriate wattage depends on target illuminance, field dimensions, mounting positions, and optical distribution. Higher wattage doesn’t necessarily reduce the number of fixtures required. Compare suitable models using photometric calculations that account for both illuminance levels and uniformity across the playing area.

The best beam angle depends on the distance between the fixture and its target area, pole height, aiming direction, and required coverage. Narrow beams concentrate light over smaller angular regions, while wider beams cover larger areas. STARLAKE offers 15°–60° options across its stadium lighting series, with availability varying by model.

Fixture quantity depends on field dimensions, competition requirements, mounting heights, pole positions, and the photometric performance of the selected luminaires. A field with existing corner poles may need a different arrangement from one with multiple sideline poles. An IES-based lighting layout can determine the required fixture quantity and distribution.

Yes, provided the replacement system meets the required illuminance and uniformity. There is no universal LED wattage equivalent to a 1500W metal halide fixture because reflector performance, ballast losses, and mounting geometry vary. Evaluate the existing system’s input power and field illumination before selecting LED replacements.

Broadcast suitability requires verification of vertical illuminance, uniformity, color rendering, color temperature, and temporal light performance. High-speed cameras may reveal flicker that isn’t visible to spectators. Published SR04 and SR05 specifications alone do not confirm compliance with professional broadcasting requirements, so project-specific technical evaluation is necessary.

Yes. STARLAKE supports customization of optics, electrical configurations, mechanical components, branding, and packaging. Buyers should provide their target specifications, destination market, estimated order quantity, and delivery schedule. Custom configurations may require sample approval, additional testing, or certification review before production.

Have any questions?

Feel free to contact us anytime - +86 139 0248 9327